Spiral-based 3D MR thermometry
نویسندگان
چکیده
Background/introduction Real time MR thermometry, usually based on the protonresonance frequency shift, is a key aspect of MR-guided focused ultrasound procedures. The desire to monitor the entire sonicated volume has led the field towards the development of rapid, 3D methods; however, acquiring fully sampled 3D volumetric data to monitor heating is time consuming, and so fast methods must be developed in order to meet the spatial and temporal requirements for adequate monitoring of thermal therapy. The data acquisition efficiency of spiral trajectories is higher than that of Cartesian scanning. Therefore, spiral trajectories are an attractive way to improve temporal resolution while maintaining spatial resolution in MR thermometry. We have recently reported that a variation on the traditional spiral-out trajectory, called the redundant spiralin/out trajectory, has certain advantages in terms of off-resonance performance. We hypothesize this trajectory to also be advantageous for PRF thermometry. Here, we have implemented this –in/out trajectory, compared its performance in terms of the focal spot size and position shift versus a Cartesian and spiral-out acquisition, and have generated rapid 3D temperature maps using the method.
منابع مشابه
Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
BACKGROUND Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope ...
متن کاملFeasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo
BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...
متن کاملImproved k-space-based MR thermometry by joint PRF phase shift and T1/T2* attenuation estimation
Background/introduction MR temperature mapping based on the proton resonance frequency (PRF) shift is used in MR-guided focused ultrasound procedures for dosimetry and safety monitoring. While conventional PRF-shift thermometry is based on calculating a phase difference between two reconstructed MR images, Gaur et al [1,2] have recently described two algorithms that estimate temperatureinduced ...
متن کاملThree dimensional motion compensation for real-time MRI guided focused ultrasound treatment of abdominal organs
Purpose/Introduction MR-guided High Intensity Focused Ultrasound (HIFU) for the ablation of tumors in abdominal organs under freebreathing conditions poses two challenges: 1) The current organ position in 3D-space must be continuously tracked in order to reposition the focal point of the HIFU-device to avoid undesired tissue damage. 2) Phase variations due to the organ displacement must be corr...
متن کامل3D MR neurography targeted peripheral nerve ablation with MR-guided high intensity focused ultrasound (MR-HIFU): initial results of a feasibility study in a swine model
Background/introduction MR-guided HIFU is an effective treatment for metastatic bone pain through periosteal nerve ablation,[1] and is being investigated for treating back pain through facet joint denervation.[2] For peripheral neuropathy, ultrasound-guided HIFU has been investigated preclinically as a means of achieving either an irreversible conduction block to treat severe spasticity [3], or...
متن کامل