In vitro performance assessment of distal protection filters: pulsatile flow conditions.

نویسندگان

  • Gail M Siewiorek
  • Mark H Wholey
  • Ender A Finol
چکیده

PURPOSE To evaluate in vitro the capture efficiency of a distal protection filter (DPF) used during carotid artery stenting and examine the longitudinal vascular impedance in the presence of a DPF. METHODS Four approved DPFs (Spider RX, FilterWire EZ, RX Accunet, and FiberNet) were evaluated in a physiologically realistic in vitro setup. A pulsatile programmable piston pump circulated a blood analog at a time-varying flow rate representative of the human common carotid artery. A silicone carotid bifurcation having average human dimensions was used for the carotid flow model. Microspheres ranging from 40 to 900 microm were injected to simulate embolization. The longitudinal vascular impedance was calculated as the ratio of the time-varying pressure gradient across the DPF to the time-varying flow rate in the internal carotid artery. RESULTS RX Accunet had the highest capture efficiency (99.4%) and Spider RX the lowest (78.1%). Spider RX increased the longitudinal vascular impedance the least after deployment (+23%), while FilterWire EZ increased the longitudinal vascular impedance the least after particles were injected (+29%). FiberNet increased longitudinal vascular impedance the most (+84%). CONCLUSION This investigation, unique for examining the effects of physiologically realistic pulsatile flow on DPF performance, can aid in the development of future generations of novel DPFs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

2D Computational Fluid Dynamic Modeling of Human Ventricle System Based on Fluid-Solid Interaction and Pulsatile Flow

Many diseases are related to cerebrospinal .uid (CSF) hydrodynamics. Therefore, understanding the hydrodynamics of CSF .ow and intracranial pressure is helpful for obtaining deeper knowledge of pathological processes and providing better treatments. Furthermore, engineering a reliable computational method is promising approach for fabricating in vitro models which is essential for inventing gen...

متن کامل

A method for determining the reference effective flow areas for mechanical heart valve prostheses: in vitro validation studies.

BACKGROUND The anatomic opening area (AOA) is usually reported as the primary index of mechanical heart valve function. Because flow contracts immediately distal to an orifice as a result of the vena contracta effect, AOA may not be a good measure of true effective flow area. METHODS AND RESULTS Laser flow imaging was used to visualize the contraction in the jet flow stream as it passed throu...

متن کامل

Optimal in vitro realization of pulsatile coronary artery flow waveforms using closed-loop feedback algorithms with multiple flow control devices

In this paper, we study optimal in vitro realization of pulsatile coronary artery flows using newly proposed closed-loop feedback algorithms with a clearly defined mathematical performance objective, and we compare several flow control device technologies in terms of their ability to generate pulsatile flow signals as accurately as possible. In the literature, there are several published result...

متن کامل

Optimization of the electrospinning process of polyurethane nanofibers and their filtration performance for use in respiratory protection mask filters

Background and Aim: Electrospun nanofibers can be used to produce filter media in personal protective equipment for the military. The present study aimed to optimize the electrospinning process used to create polyurethane nanofiber substrates and compare the optimum substrate filtration performance with a typical commercial substrate used in the structure of N95 respirators. Methods: In this ex...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2009