Body adiposity index performance in estimating body fat in a sample of severely obese Brazilian patients
نویسندگان
چکیده
BACKGROUND/OBJECTIVES The body adiposity index (BAI) estimates the amount of body fat (BF) in humans. In Mexican-American and African-American populations, BAI has performed better than body mass index (BMI). The aim of this study was to evaluate the performance of BAI in estimating percentage (BF%) in severely obese Brazilian patients, with air displacement plethysmography (ADP) used as the reference method. SUBJECTS/METHODS Estimation of BF% by ADP, anthropometric measurements (height, abdominal and hip circumferences, body weight, and BMI) and BAI calculation were performed in 72 obese subjects (BMI ≥ 30 kg/m(2)) aged 30-55 years. RESULTS The mean BF% estimates ± standard deviation were 52.1 ± 5.7 % for ADP and 47.7 ± 7.4% for BAI, with a positive Pearson correlation (rp = 0.66) and a positive Lin's concordance correlation (rc = 0.479) observed between these methods. The 95% limits of individual agreement between BAI and ADP ranged from -5.769% to 16.036%, with BAI exhibiting an average positive bias of 5.13% compared to the reference method. For each studied variable, BAI exhibited a systematic bias, as evidenced by a tendency for low BF% values to be overestimated. CONCLUSION For Brazilian patients with severe obesity, BAI does not provide an accurate estimate of BF%.
منابع مشابه
Does body adiposity index evaluate percentage of body fat?
Introduction: The purpose of the present study was to determine whether the novel marker, body adiposity index (BAI), is accurate to measure percentage of body fat (PBF). Materials and methods: Seventy-eight males were undergone anthropometric examination. PBF was calculated by BAI and measured using InBody 3.0. Results: Significant correlation was found between BAI and PBF (r = 0.751; P < ...
متن کاملBioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women
Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...
متن کاملThe Relationship between Skinfold Thickness and Body Mass Index in Estimating Body Fat Percentage on Bowen University Students
Body Mass Index (BMI) is a weight-to-height ratio used as a quick and easy guide to obesity classification. BMI of 30 or greater is indicative of excess body fat and has been labelled as increasing the risk of degenerative diseases such as cardiovascular disease and diabetes. Body fat percentage is also assessed through skinfold thickness measurement.. The aim of this study was to estimate the ...
متن کاملA Randomized Controlled Trial of the Effects of Supervised Aerobic Training Program on Anthropometry, Lipid Profile and Body Composition in Obese Adult Leukemic Patients
Background: The purpose of this randomized study was to examine the effects of a supervised aerobic training program on anthropometry, lipid profile and body composition of obese adult leukemia survivors. Methods: Fifty-four obese adult leukemia survivors were allocated randomly into two groups of equal number. The intervention group underwent a supervised aerobic training program for 30-40 mi...
متن کاملClassification of different degrees of adiposity in sedentary rats
In experimental studies, several parameters, such as body weight, body mass index, adiposity index, and dual-energy X-ray absorptiometry, have commonly been used to demonstrate increased adiposity and investigate the mechanisms underlying obesity and sedentary lifestyles. However, these investigations have not classified the degree of adiposity nor defined adiposity categories for rats, such as...
متن کامل