Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs.
نویسندگان
چکیده
OBJECTIVE Performance criteria have been established for in vitro blood glucose monitoring, particularly for the self-monitoring of blood glucose using glucose meters. Devices intended for use in the future, such as the continuous glucose monitoring system (CGMS), should satisfy similar criteria, particularly in diabetic patients under intensive therapy. RESEARCH DESIGN AND METHODS The analysis was conducted on 18 type 1 diabetic patients (not controlled, HbA(1c) >7.5%) treated by external pump using insulin analogs. Each patient received a glucose sensor for 3 days during his/her hospitalization and was instructed in its operation. Medtronic criteria were used to determine the accuracy of the CGMS. In addition, the data were analyzed according to American Diabetes Association (ADA) criteria, Clarke Error Grid analysis, and method of residuals, with the glucose oxidase method using a Beckman analyzer used as the reference method. Specificity and sensitivity were evaluated from the viewpoint of accuracy in the detection of hypoglycemia. For nine patients, two glucose sensors were simultaneously inserted into an abdominal site to determine the reproducibility of the system. RESULTS-Among the 33 glucose sensors inserted, 6 (18%) were nonfunctional. The mean duration of CGMS recording was 63 +/- 12 h. From all of the 692 sets of data that paired glucose readings and CGMS, the coefficients of correlation ranged from 0.87 to 0.92 and the mean absolute error ranged from 12.8 to 15.7%. The time experienced in hypoglycemia (<55 mg/dl) was reported at 86 +/- 62 min/day. Only 39% of the CGMS values satisfied the ADA precision criteria to within +/-10%, and 19% of these values satisfied the future ADA precision criteria of accuracy to within +/-5%. The means of difference method showed that the CGMS slightly underestimated the plasma glucose values (mean = -12 mg/dl). Error grid analysis showed only 77% of the glucose sensor values were in zone A, and 98.9% were in zones A and B. Two values fell in zone C and a single value fell in zone D. The sensitivity and specificity of the CGMS to detect hypoglycemia were 33 and 96%, respectively. A total of 6666 paired sensor values were recorded with a coefficient of correlation of 0.84 with a coefficient of variation of 8.25%. CONCLUSIONS CGMS could be useful in routine clinical practice to provide much more information on the glucose profile than intermittent self-monitoring of blood glucose (SMBG). However, CGMS cannot be used as a replacement for glucose meters because it does not satisfy the conventional performance goals set down for in vitro glucose measurements and could therefore lead to clinically incorrect treatment decisions.
منابع مشابه
Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)
OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...
متن کاملReduction of blood glucose variability in type 1 diabetic patients treated by pancreatic islet transplantation: interest of continuous glucose monitoring.
OBJECTIVE To compare the glycemic profiles of patients with type 1 diabetes treated with either an implantable insulin pump or pancreas or islet transplantation by the means of the continuous glucose monitoring system (CGMS; Minimed, Sylmar, CA). RESEARCH DESIGN AND METHODS The CGMS enabled recording of subcutaneous glucose concentrations (range 2.2-22 mmol/l) over 72 h (288 measurements per ...
متن کاملSafety of various methods of intensive insulin therapy in hospital condition assessed by hypoglycaemic episodes detected with the use of continuous glucose monitoring system.
PURPOSE The aim of the study was to determine the safety of three intensive insulin therapy methods: multiple daily insulin injections (MDI), continuous subcutaneous insulin infusion (CSII) and continuous intravenous insulin infusion (IVII) used in poorly controlled type 2 diabetic patients in hospital condition. The safety of these intensive insulin therapy methods was measured by the assessme...
متن کاملSafety of insulin glulisine when given by continuous subcutaneous infusion using an external pump in patients with type 1 diabetes.
This twelve-week, European, multicenter, controlled, open-label, randomized (1 : 1), parallel-group trial compared the safety of insulin glulisine with insulin as part used in continuous subcutaneous insulin infusion. Patients with type 1 diabetes (n=59) and continuous subcutaneous insulin infusion experience (mean values: HbA1c 6.9 % [insulin glulisine: 6.8 % VS. insulin as part: 7.1 %]; age 4...
متن کاملThe continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control.
OBJECTIVE To evaluate whether the continuous glucose monitoring system (CGMS; MiniMed, Sylmar, CA) is useful for investigating the incidence of unrecognized hypoglycemias in type 1 and type 2 diabetic patients and for improving metabolic control in type 1 diabetic patients. RESEARCH DESIGN AND METHODS A total of 70 diabetic subjects (40 type 1 and 30 type 2 subjects) were monitored using the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diabetes care
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2003