The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome
نویسندگان
چکیده
Purpose The purpose of this study was to determine the effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis (LASIK). Methods This is a prospective controlled non-randomized, institutional study. Patients underwent either epi-LASIK with mitomycin (advanced surface ablation [ASA]), thin-flap LASIK (90 µm head), or thick-flap LASIK (130 µm head). In ASA, the Moria Epi-K hydroseparator was used. LASIK flaps were created using the Moria M-2 mechanical microkeratome. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured preoperatively and 3 months after surgery, using the Ocular Response Analyzer®. Results Ten patients (19 eyes) underwent ASA, 11 patients (16 eyes) underwent thin-flap LASIK, and 11 patients (16 eyes) underwent thick-flap LASIK. The mean preoperative CH was 10.47±0.88, 10.52±1.4, and 11.28±1.4 mmHg (p=0.043), respectively, decreasing after surgery by 1.75±1.02, 1.66±1.00, and 2.62±1.03 mmHg (p=0.017). The mean reduction of CH per micron of central corneal ablation was 0.031, 0.023, and 0.049 mmHg/µm (p=0.005). Mean preoperative CRF was 10.11±1.28, 10.34±1.87, and 10.62±1.76 mmHg (p=0.66), decreasing after surgery by 2.33±1.35, 2.77±1.03, and 2.92±1.10 mmHg (p=0.308). The mean reduction of CRF per micron of central corneal ablation was 0.039, 0.040, and 0.051 mmHg/µm (p=0.112). Conclusion Thick-flap LASIK caused a greater reduction of CH and CRF than thin-flap LASIK and ASA, although this was statistically significant only for CH. ASA and thin-flap LASIK were found to be biomechanically similar.
منابع مشابه
Factors Influencing Intraocular Pressure Changes after Laser In Situ Keratomileusis with Flaps Created by Femtosecond Laser or Mechanical Microkeratome
The aim of this study is to describe factors that influence the measured intraocular pressure (IOP) change and to develop a predictive model after myopic laser in situ keratomileusis (LASIK) with a femtosecond (FS) laser or a microkeratome (MK). We retrospectively reviewed preoperative, intraoperative, and 12-month postoperative medical records in 2485 eyes of 1309 patients who underwent LASIK ...
متن کاملCorneal flap thickness with the Moria M2 single-use head 90 microkeratome in 72 consecutive LASIK procedures
PURPOSE This study aimed to evaluate the accuracy and consistency of corneal flap thickness in laser-assisted in situ keratomileusis (LASIK) with the Moria M2 single-use head 90 microkeratome. METHODS The central corneal thickness of 72 (37 right, 35 left) eyes of 37 patients was measured by ultrasonic pachymetry preoperatively and intraoperatively after flap cut. The Moria M2 single-use head...
متن کاملCorneal flap thickness with the Moria M2 single-use head 90 microkeratome.
PURPOSE To analyse the accuracy of corneal flap thickness created in laser-assisted in situ keratomileusis (LASIK) using the Moria Model 2 (M2) single-use head 90 microkeratome. METHODS The corneal thickness of 300 (266 myopic and 34 hyperopic) eyes of 150 patients was measured by ultrasonic pachymetry preoperationally and intraoperationally after flap cut. The Moria M2 single-use head 90, in...
متن کاملIn vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.
PURPOSE To assess and compare corneal modifications induced by IntraLase PulsionFS femtosecond laser and mechanical microkeratome Hansatome for laser in situ keratomileusis (LASIK) using the new-generation Heidelberg Retina Tomograph II (HRT II)/Rostock Cornea Module confocal microscope. METHODS In this case-control study, 24 eyes of 12 patients were examined with the HRT II in the follow-up ...
متن کاملBlade source effect on laser in situ keratomileusis flap thickness with the Amadeus I microkeratome.
PURPOSE To determine the effect of different blades on laser in situ keratomileusis (LASIK) flap thickness created with the Amadeus I microkeratome (Ziemer Ophthalmic Systems). SETTING Emory University Department of Ophthalmology and Emory Vision, Atlanta, Georgia, USA. METHODS This retrospective nonrandomized comparative case study from January 2005 through June 2006 compared LASIK flap th...
متن کامل