Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
نویسندگان
چکیده
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.
منابع مشابه
Motion-Artifact Resistant Design of Photoplethysmograph Ring Sensor for Driver Monitoring
Through extensive literature search, it has been found that there exists strong correlation between the Mental Workload of an automobile driver with his or her physiological measurements, especially the Heart Rate Variability (HRV) measurements. In order to make a driver's HRV monitoring on the road possible, a new photoplethysmograph (PPG) Ring Sensor prototype has been devised specifically fo...
متن کاملComparison between Electrocardiographic and Earlobe Pulse Photoplethysmographic Detection for Evaluating Heart Rate Variability in Healthy Subjects in Short- and Long-Term Recordings
Heart rate variability (HRV) is commonly used to assess autonomic functions and responses to environmental stimuli. It is usually derived from electrocardiographic signals; however, in the last few years, photoplethysmography has been successfully used to evaluate beat-to-beat time intervals and to assess changes in the human heart rate under several conditions. The present work describes a sim...
متن کاملIn-Ear Pulse Wave Measurements: A Pilot Study.
The measurement of the Pulse wave Arrival Time (PAT) has proven to be a vital tool in medical diagnosis. Whereby most PAT measurements are carried out at extremities, this work proposes the interior of the ear as a new site. Due to pressure variations inside the auditory canal a pulse wave can be measured by using a pressure sensor or by simple in-ear headphones. To verify the signal origin, a ...
متن کاملAnalysis of Reflectance Photoplethysmograph Sensors
Photoplethysmography is a simple measurement of the variation in blood volume in tissue. It detects the pulse signal of heart beat as well as the low frequency signal of vasoconstriction and vasodilation. The transmission type measurement is limited to only a few specific positions for example the index finger that have a short path length for light. The reflectance type measurement can be conv...
متن کاملActive motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
This paper presents an active noise cancellation technique for recovering wearable biosensor signals corrupted by bodily motion. A finger mounted photoplethysmograph (PPG) ring sensor with a collocated MEMS accelerometer is considered. The system by which finger acceleration disturbs PPG output is identified and a means of modeling this relationship is prescribed using either FIR or Laguerre mo...