Brain SPECT artifacts in patients having metallic cranioplasty.
نویسندگان
چکیده
OBJECTIVE Over the past few years, we have performed several brain SPECT studies on patients who have had previous head trauma that required metallic cranioplasty. Transaxial images showed clearly defined photon-deficient areas extending from the brain tissue into the area of the scalp. To investigate the extent and pattern of this type of artifact, SPECT brain phantom studies were performed and compared with the patient studies. METHODS SPECT brain phantom studies were performed using various metallic sheets to simulate metallic plates that were used for cranioplasty. RESULTS Phantom studies using lead to represent tantalum plates were similar to our patient studies; that is, the photon-deficient area in normal brain tissue extended into the area where normal scalp activity would be. There was also increased tracer activity at the periphery of the photon-deficient area that extended to where normal scalp activity would be. This was similar to the patient studies and was not present on the phantom studies done without any metallic sheets present. CONCLUSION One would expect photon-deficient artifacts caused by radiopaque metallic plates in brain SPECT studies. The patient and phantom studies demonstrate that an increased tracer activity artifact is also present at the periphery of the photon-deficient area that extends into the area of the scalp. Knowing the appearance of this type of artifact caused by radiopaque metallic plates in brain SPECT studies could be beneficial, especially in cases with poor patient history and lacking radiographic correlation.
منابع مشابه
Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملFeasibility of the custom-made titanium cranioplasty CRANIOTOP®
BACKGROUND With decompressive craniectomy for ischemic stroke, traumatic brain injury, and skull-infiltrating tumors, the need for cranioplasty has increased. Different materials for custom-made cranioplasties have been evaluated, but a gold standard could not yet be established. We report our experience with the new custom-made titanium CRANIOTOP(®)cranioplasty (CL Instruments, Germany). MET...
متن کاملAnalysis of the Risk Factors Affecting the Surgical Site Infection after Cranioplasty Following Decompressive Craniectomy
OBJECTIVE The risk factors for surgical site infections (SSIs) after cranioplasty following decompressive craniectomy remain unclear. The goal of this study was to analyze the risk factors related to developing SSIs after cranioplasty and to suggest valuable predictors. METHODS A retrospective review was conducted of patients who underwent cranioplasty following decompressive craniectomy at o...
متن کاملEvaluation of role of brain SPECT in diagnosis of post stroke dementia [Persian]
Post stroke dementia is one of the most common complications of stroke that is preventable and relatively treatable too. The purpose of the study is comparison between the positive findings in brain CT scan and brain perfusion SPECT. 15 patients who were complicated by dementia after cerebrovascular accident and also 5 patients as a control group enrolled in this study. Brain CT scan and ...
متن کاملComparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]
Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2001