Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach
نویسندگان
چکیده
BACKGROUND Complex AO type C3 fractures of the distal femur are challenging injuries, fraught with complications such as malunion and stiffness. We prospectively evaluated a consecutive series of patients with complex AO type C3 distal femur fractures to determine the clinicoradiological outcome after fixation with a single locked plate using modified swashbuckler approach. MATERIALS AND METHODS 12 patients with C3 type distal femur fractures treated with a lateral locked plate, using a modified swashbuckler approach, were included in the study. The extraarticular component was managed either by compression plating or bridge plating (transarticular approach and retrograde plate osteosynthesis) depending on the fracture pattern. Primary bone grafting was not done in any case. The clinical outcome at 1 year was determined using the Knee Society Score (KSS). The presence of any secondary osteoarthritis in the knee joint was noted at final followup. RESULTS All fractures united at a mean of 14.3 ± 4.7 weeks (range 6-26 weeks). There were no significant complications such as nonunion, deep infection, and implant failure. One of the patients underwent secondary bone grafting at 3 months. The mean range of motion of the knee was 120° ± 14.8° (range 105°-150°). Seven patients had excellent, three patients had good and two patients had a fair outcome according to the KSS at 1 year. At a mean followup of 17.6 months, three patients showed radiological evidence of secondary osteoarthritis of the knee joint. However, only one of these patients was symptomatic. CONCLUSION The results of complex C3 type distal femur fractures, fixed with a single lateral locked plate using a modified swashbuckler approach, are encouraging, with a majority of patients achieving good to excellent outcome at 1 year.
منابع مشابه
Approach to distal femur by osteotomy of the patellar distal pole and internal fixation with basket plate in complex articular fracture: report of five cases.
According to AO classification, 33-C3 (complete articular multifragmentary) fracture of distal femur is characterized by complex articular involvement, along with short distal femoral block with multiple small fragments and usually with severe soft tissue abruption. In such cases of complex articular fracture of distal femur with extensive comminution of the femur condyle that is often seen in ...
متن کاملTransarticular approach and retrograde plate osteosynthesis (TARPO) using implants with angular stability -- a series of 17 cases of complex distal femoral fractures type C3/AO.
AIM The aim of this retrospective study was to evaluate the outcome of distal femoral fractures type C3 AO, using TARPO technique and plates with angular stability. MATERIAL AND METHODS The study included 17 fractures type C3 AO, with 4 open fractures: 1 type I, 1 type II, and 2 type IIIA with bone loss Gustilo. All patients were operated by TARPO technique using Less Invasive Stabilization S...
متن کاملبررسی نتایج درمان جراحی شکستگیهای داخل مفصلی دیستال استخوان بازو (بررسی 46 بیمار)
Background and Aim: Intra-articular fractures of distal humerus in adults present a controversial challenge for orthopedic surgeons. Minor irregularities of the joint surface of the elbow usually cause some loss of function. This can usually be minimized by early, accurate open reduction with sufficiently rigid fixation to permit immediate motion. The posterior approach combined with Olecra...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملImmediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.
Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, som...
متن کامل