Rapid simultaneous determination of multiple pesticide residues in traditional Chinese medicines using programmed temperature vaporizer injection-fast gas chromatography coupled with mass spectrometry.

نویسندگان

  • Gang Du
  • Yuelin Song
  • Yitao Wang
چکیده

A fast gas chromatography coupled with mass spectrometry (GC-MS) using large volume injection with programmed temperature vaporizer in solvent vent mode (PTV-LVI-SV) was developed for the trace determination of multiple pesticide residues in traditional Chinese medicines (TCMs). Experimental conditions of PTV-LVI-SV injection were optimized by central composite design. The optimized result was that initial temperature was held at 40°C for 39 s, vent flow rate was set at 45 mL/min and vent pressure was held at 0 psi for 36 s, injection volume was 10 μL. Furthermore, the quick and effective QuEChERS (quick, easy, cheap, effective, rugged and safe) method was performed to extract and purify pesticide residues in TCMs. The prepared samples were analyzed with GC-MS in the selected ion monitoring mode (SIM). The lowest LOD was 4 μg/kg for some pesticides. The recoveries were checked by spiking samples with pesticides at 25, 50 and 250 μg/kg. The average recoveries of most pesticides were from 80 to 118%. The result indicated that QuEChERS and PTV-LVI-SV GC-MS method was a rapid and sensitive analysis technique for the determination of multiple pesticide residues in TCMs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid analysis of multiple pesticide residues in fruit-based baby food using programmed temperature vaporiser injection-low-pressure gas chromatography-high-resolution time-of-flight mass spectrometry.

A rapid method using programmed temperature vaporiser injection-low-pressure gas chromatography-high-resolution time-of-flight mass spectrometry (PTV-LP-GC-HR-TOF-MS) for the analysis of multiple pesticide residues in fruit-based baby food was developed. The fast and inexpensive buffered QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction method and "conventional" approach tha...

متن کامل

[Rapid determination of 129 pesticide residues in vegetables and fruits by gas chromatography-triple quadrupole mass spectrometry].

An analytical method for the simultaneous determination of 129 pesticides in vegetables and fruits was established based on optimized QuEChERS with gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). The samples were extracted with acetonitrile (containing 1% (v/v) acetic acid), then the extracts were determined by GC-MS/MS in multireaction monitoring (MRM) mode after being clean...

متن کامل

Blocked Design for the Robustness Study in the 1 Determination of Dichlobenil and Bam in Onions by 2 Programmed Temperature Vaporizer - Gas Chromatography - 3 Mass Spectrometry 4 5

AD-HOC BLOCKED DESIGN FOR THE ROBUSTNESS STUDY IN THE 1 DETERMINATION OF DICHLOBENIL AND BAM IN ONIONS BY 2 PROGRAMMED TEMPERATURE VAPORIZER-GAS CHROMATOGRAPHY3 MASS SPECTROMETRY 4 5 Ana Herrero, Celia Reguera, M. Cruz Ortiz, Luis A. Sarabia, M. Sagrario Sánchez 6 Dept. of Chemistry, Dept. of Mathematics and Computation 7 Faculty of Sciences, University of Burgos 8 Plaza Misael Bañuelos s/n, 09...

متن کامل

Gel Permeation Chromatography Purification and Gas Chromatography-Mass Spectrometry Detection of Multi-Pesticide Residues in Traditional Chinese Medicine

The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chromatography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractan...

متن کامل

Determination of Pesticide Residues in Honey using the GC×GC-TOFMS Technique

In this study, a QuEChERS method and gas chromatography coupled with time-of-flight mass spectrometry (GC×GCTOFMS) was developed for rapid extraction and simultaneous determination of 12 pesticide residues in honey. The GC×GC-TOFMS method was validated according to the SANCO guidance in terms of linearity, selectivity, reproducibility and recovery. Regarding the results, recovery rates ranged b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of separation science

دوره 34 23  شماره 

صفحات  -

تاریخ انتشار 2011