Validation of heart rate monitor-based predictions of oxygen uptake and energy expenditure.

نویسندگان

  • Paul G Montgomery
  • Daniel J Green
  • Naroa Etxebarria
  • David B Pyne
  • Philo U Saunders
  • Clare L Minahan
چکیده

To validate VO2 and energy expenditure predictions by the Suunto heart rate (HR) system against a first principle gas analysis system, well-trained male (n = 10, age 29.8 +/- 4.3 years, VO2 65.9 +/- 9.7 ml x kg x min) and female (n = 7, 25.6 +/- 3.6 years, 57.0 +/- 4.2 ml x kg x min) runners completed a 2-stage incremental running test to establish submaximal and maximal oxygen uptake values. Metabolic cart values were used as the criterion measure of VO2 and energy expenditure (kJ) and compared with the predicted values from the Suunto software. The 3 levels of software analysis for the Suunto system were basic personal information (BI), BI + measured maximal HR (BIhr), and BIhr + measured VO2 (BIhr + v). Comparisons were analyzed using linear regression to determine the standard error of the estimate (SEE). Eight subjects repeated the trial within 7 days to determine reliability (typical error [TE]). The SEEs for oxygen consumption via BI, BIhr, and BIhr + v were 2.6, 2.8, and 2.6 ml.kg.min, respectively, with corresponding percent coefficient of variation (%CV) of 6.0, 6.5, and 6.0. The bias compared with the criterion VO2 decreased from -6.3 for BI, -2.5 for BIhr, to -0.9% for BIhr + v. The SEE of energy expenditure improved from BI (6.74 kJ) to BIhr (6.56) and BIhr + v (6.14) with corresponding %CV of 13.6, 12.2, and 12.7. The TE values for VO2 were approximately 0.60 ml x kg x min and approximately 2 kJ for energy expenditure. The %CV for VO2 and energy expenditure was approximately 1 to 4%. Although reliable, basic HR-based estimations of VO2 and energy expenditure from the Suunto system underestimated VO2 and energy expenditure by approximately 6 and 13%, respectively. However, estimation can be improved when maximal HR and VO2 values are added to the software analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart rate as a predictor of energy expenditure in people with spinal cord injury.

This study evaluated the accuracy of heart rate calibrated from a maximum exercise test for predicting energy expenditure during five activities of daily living (ADL) in participants with spinal cord injury (SCI). Thirteen individuals with SCI underwent maximum exercise testing, followed by portable heart rate and metabolic testing during five ADL. A regression equation was developed from heart...

متن کامل

Validation of the Actiheart Monitor for the Measurement of Physical Activity

Int J Exerc Sci 2(1) : 60-71, 2009. The Actiheart monitor uniquely allows simultaneous measurement of heart rate and movement counts. The purpose of this study was to establish validity evidence for the Actiheart monitor under laboratory and free-living conditions. A total of 34 college students (17 males and 17 females, age = 21.8 ± 3.6 years) participated in the study. In the laboratory envir...

متن کامل

Estimating Energy Expenditure from Heart Rate in Older Adults: A Case for Calibration

BACKGROUND Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. OBJECTIVE To assess the validity and re...

متن کامل

تاثیر ارتز میلواکی بر شاخص‌های مصرف انرژی نوجوانان پسر مبتلا به کایفوز متحرک ناحیه توراسیک

    Background & Aim: Apart from poor cosmetic appearance, the most important potential consequence of spinal deformities is cardiorespiratory function. However, one of the reasons that patients discontinue wearing orthosis seems to be an increase in energy expenditure during activity apart from its cosmetic problem. The purpose of this study was to assess the effect of Milwaukee brace on energ...

متن کامل

Physiologic responses and energy expenditure of kinect active video game play in schoolchildren.

OBJECTIVE To evaluate the physiologic responses and energy expenditure of active video gaming using Kinect for the Xbox 360. DESIGN Comparison study. SETTING Kirkby Sports College Centre for Learning, Liverpool, England. PARTICIPANTS Eighteen schoolchildren (10 boys and 8 girls) aged 11 to 15 years. MAIN EXPOSURE A comparison of a traditional sedentary video game and 2 Kinect activity-p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of strength and conditioning research

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2009