A state of the art X-ray micro-CT scanner takes about 20 seconds to acquire a full dataset, which is too slow to capture the rapidly beating heart of small animals. We have been working to develop the first electron-beam micro-CT (EBMCT) prototype for cardiac imaging of the mice and rats. In this paper, we describe the background on electron-beam CT (EBCT) and emphasize the needs for EBMCT. Then, we present a top-level design and a preliminary physical analysis for the first EBMCT scanner. The proposed EBMCT prototype would allow 0.03-0.01s temporal resolution (35-70 half-scans per second) with 0.2mm spatial resolution and 5% contrast resolution. Finally, we discuss a few related issues to further highlight that this project is not only important for basic biomedical research but also feasible technically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition

Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...

متن کامل

Design, analysis and simulation for development of the first clinical micro-CT scanner.

In this article, we propose to develop the first clinical micro-CT (CMCT) system for human temporal bone imaging in vivo. This CMCT system consists of medical CT and micro-CT scanners either as separate components or in a combination, a cross-modality registration mechanism such as a facial surface scanner, and associated software. This system integrates the strengths of state-of-the-art medica...

متن کامل

Free Vibration Analysis of SVC Systems Based on Reddy-Levinson Model Using DQM

In this study, the free vibration analysis of smart vibration control (SVC) systems based on Reddy – Levinson model and modified strain gradient theory is developed. This system consist of a micro beam at middle and two magneto-electro-elastic (MEE) composite micro beams at top and bottom which connected by enclosing elastic medium and simulated by Winkler and Pasternak foundation. The effects ...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Mechanical Behavior of a FGM Capacitive Micro-Beam Subjected to a Heat Source

This paper presents mechanical behavior of a functionally graded (FG) cantilever micro-beam subjected to a nonlinear electrostatic pressure and thermal moment considering effects of material length scale parameters. Material properties through the beam thickness direction are graded. The top surface of the micro-beam is made of pure metal and the bottom surface from a mixture of metal and ceram...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004