Effect of cataract surgery incision location and intraocular lens type on ocular aberrations.
نویسندگان
چکیده
PURPOSE To determine whether Hartmann-Shack wavefront sensing detects differences in optical performance in vivo between poly(methyl methacrylate) (PMMA) and foldable acrylic intraocular lenses (IOLs) and between clear corneal and scleral tunnel incisions and whether optical differences are manifested as differences in visual performance. SETTING Department of Optometry, University of Bradford, West Yorkshire, United Kingdom. METHODS This study comprised 74 subjects; 17 were phakic with no ocular pathology, 20 had implantation of a Pharmacia 722C PMMA IOL through a scleral tunnel, 21 had implantation of an Alcon AcrySof IOL through a scleral tunnel, and 16 had implantation of an AcrySof IOL through a corneal incision. Visual acuity and contrast sensitivity testing, ocular optical quality measurement using Hartmann-Shack wavefront sensing, and corneal surface measurement with a videokeratoscope were performed in all cases. RESULTS There were significant differences between groups in the total root-mean-square (RMS) wavefront aberration over a 6.0 mm pupil (F=3.91; degrees of freedom=3,70; P<.05) mediated at the 4th-order RMS, specifically spherical and tetrafoil aberrations. The PMMA-scleral group had the least aberrations and the AcrySof-corneal group the most. For a 3.5 mm diameter pupil, the total higher-order RMS wavefront aberration was not significantly different between the groups (P>.05). There were no differences between groups in corneal shape, visual acuity, or contrast sensitivity. CONCLUSIONS Implantation of the spherical PMMA IOL led to a slight reduction in total wavefront aberration compared to phakic eyes. AcrySof IOLs induced more aberrations, especially spherical aberration. Corneal-based incisions for IOL implantation compounded this increase. Studies of the optical performance of IOLs in vivo should use wavefront sensing as the main outcome measure rather than visual measures, which are readily confounded by multiple factors.
منابع مشابه
Aspheric microincision intraocular lens implantation with biaxial microincision cataract surgery: efficacy and reliability.
PURPOSE To evaluate the efficacy and reliability of a microincision intraocular lens (IOL) and its use in biaxial microincision cataract surgery (MICS). SETTING Atatürk Training and Research Hospital, Ankara, Turkey. DESIGN Prospective clinical study. METHODS A microincision IOL (Akreos MI60) was implanted after cataract extraction by the biaxial MICS technique. Over a postoperative follo...
متن کاملIntraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery.
AIM To compare the optical outcomes of biaxial microincision cataract surgery (B-MICS) versus coaxial small-incision cataract surgery (C-SICS). METHODS Thirty patients (sixty eyes) with bilateral age-related cataract underwent B-MICS through a 1.7 mm clear corneal incision (CCI) in one eye and C-SICS through a 2.8-mm CCI in the other eye. Every eye was implanted with a micro-incision aspheric...
متن کاملAre changes in ocular aberrations with age a significant problem for refractive surgery?
We discuss current knowledge about the change of aberrations with aging, cataract surgery, and laser in situ keratomileusis (LASIK) for myopia. Based on this evidence, we speculate about the long-term expectations for postoperative LASIK eyes in terms of aberrations. Standard myopic LASIK surgery produces a significant increase in aberrations, particularly corneal spherical aberration, which ch...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملOptical aberrations of intraocular lenses measured in vivo and in vitro.
Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not signif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 31 4 شماره
صفحات -
تاریخ انتشار 2005