Voxel Similarity Measures for Automated Image Registration
نویسندگان
چکیده
We present the concept of the feature space sequence: 2D distributions of voxel features of two images generated at registration and a sequence of misregistrations. We provide an explanation of the structure seen in these images. Feature space sequences have been generated for a pair of MR image volumes identical apart from the addition of Gaussian noise to one, MR image volumes with and without Gadolinium enhancement, MR and PET-FDG image volumes and MR and CT image volumes, all of the head. The structure seen in the feature space sequences was used to devise two new measures of similarity which in turn were used to produce plots of cost versus misregistration for the 6 degrees of freedom of rigid body motion. One of these, the third order moment of the feature space histogram, was used to register the MR image volumes with and without Gadolinium enhancement. These techniques have the potential for registration accuracy to within a small fraction of a voxel or resolution element and therefore interpolation errors in image transformation can be the dominant source of error in subtracted images. We present a method for removing these errors using sinc interpolation and show how interpolation errors can be reduced by over two orders of magnitude.
منابع مشابه
Automatic Estimation of Error in Voxel-Based Registration
Image registration driven by similarity measures that are simple functions of voxel intensities is now widely used in medical applications. Validation of registration in general remains an unsolved problem; measurement of registration error usually requires manual intervention. This paper presents a general framework for automatically estimating the scale of spatial registration error. The erro...
متن کاملSurface-Similarity vs. Voxel-Similarity Based Registration of Multimodality Medical Images using Simulated Annealing
This paper develops a framework for research in the eld of multimodality image registration. A certain formal treatment of the registration problem is proposed. We discuss some aspects of the surface and voxel-similarity measures in a context of simulated annealing based optimization.
متن کاملAutomated 3D Registration of Truncated MR and CT Images of the Head
This paper presents a fully automated technique for the rigid body registration of clinically acquired MR and CT images of the head. We describe our multiresolution approach to the optimisation of voxel similarity measures and evaluate the performance of a number of measures when presented with clinical images with a small overlapping volume. Results are compared with those derived from manual ...
متن کاملVoxel similarity based automatic image registration
Description: We proposed a fast, fully automatic registration algorithm that is capable of solving unimodality or multimodality registration problems in 2D or 3D. Many similarity measures were proposed in the past decade. We chose the measures based on the mutual information of the images proposed by Collignon et al. and Viola and Wells, and on the normalized mutual information of the images pr...
متن کاملAn Algorithm for 3D Registration of Multi-Modality Medical Images by Use of Voxel-Similarity-Based Measures
0. Abstract This report describes work done within a practical training at the Philips Research Laboratories / Technical Systems Hamburg in 1995. My work was concerned with the development and implementation of a completely automatic image registration algorithm that uses a voxel-similarity-based measure as matching criterion. Both singleand multi-modality 3D medical images can be processed. Fu...
متن کامل