Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study.

نویسندگان

  • Eriberto Bressan
  • Gianluca Paniz
  • Diego Lops
  • Boris Corazza
  • Eugenio Romeo
  • Gianantonio Favero
چکیده

PURPOSE The aim of this clinical research on implant-supported restorations is to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri-implant soft tissue. MATERIAL AND METHODS Twenty patients received an endosseous dental implant in the anterior maxilla. At the time of each definitive prosthesis delivery, an all-ceramic crown has been tried on gold, titanium and zirconia abutment. After the insertion of each single abutment, the peri-implant soft tissue color has been measured through a spectrophotometer. Also, the thickness of the facial peri-implant soft tissue was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a specific tissue area and to collect the data before the statistical analysis in Lab* color space. The normality of the quantitative variables was verified by means of the Shapiro-Wilk test. Simple linear correlation between quantitative variables was evaluated by using Pearson's coefficient. The results on the performance of the abutment materials with regard to the color measurements and the overall measurement ΔE were described by computing the least-square means. The significance of differences among types of abutment was verified by means of the Scheffe test for multiple comparisons. RESULTS For all the abutments used, the color of the peri-implant soft tissue appeared to be significantly different from the one of the contra-lateral tooth (ΔE>8.5). Significantly higher (P<0.05) difference were present with the use of titanium abutments (11 ± 0.4) when compared with the results of gold (8.9 ± 0.4) and zirconia (8.5 ± 0.4) abutments. No correlation has been demonstrated between soft tissue thickness and degree of color difference (P>0.25). CONCLUSIONS Within the limitation of the present study, the peri-implant soft tissue color appears to be different from the soft tissue color around natural teeth, no matter which type of restorative material is selected. When titanium abutment was selected, significantly higher differences were present than those obtained with gold or zirconia abutments. The thickness of the peri-implant soft tissue did not appear to be a crucial factor in the abutment impact on the soft tissue color.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of implant abutment material on the color of different ceramic crown systems.

STATEMENT OF PROBLEM Ceramics are widely used for anterior restorations; however, clinical color reproduction still constitutes a challenge particularly when the ceramic crowns are used on titanium implant abutments. PURPOSE The purpose of this in vitro study was to investigate the effect of implant abutment material on the color of different ceramic material systems. MATERIAL AND METHODS F...

متن کامل

Long-term outcome of cemented versus screw-retained implant-supported partial restorations.

PURPOSE The present study was designed to compare the long-term outcome and complications of cemented versus screw-retained implant restorations in partially edentulous patients. MATERIALS AND METHODS Consecutive patients with bilateral partial posterior edentulism comprised the study group. Implants were placed, and cemented or screw-retained restorations were randomly assigned to the patien...

متن کامل

Seung -

Objectives: The aim of this prospective cohort study was to compute the long-term clinical survival and complication rates of alumina-toughened zirconia abutments used for implant-supported restorations and to evaluate the effects of several clinical variables on these rates. Material and methods: From May 1998 to September 2010, 213 patients aged 18 years or older were recruited. The patients ...

متن کامل

Considerations of implant abutment and crown contour: critical contour and subcritical contour.

Adequately contoured implant restorations need to transition from the circumferential design of the implant head to the correct cervical tooth anatomy. The implant abutment may be used to effect this transition provided there is sufficient running room. Implant restorations have been described as overcontoured, flat, and undercontoured. It has been shown that overcontouring will generally cause...

متن کامل

Influence of Restorative Materials on Color of Implant-Supported Single Crowns in Esthetic Zone: A Spectrophotometric Evaluation

Restorations of 98 implant-supported single crowns in anterior maxillary area were divided into 5 groups: zirconia abutment, titanium abutment, and gold/gold hue abutment with zirconia coping, respectively, and titanium abutment with metal coping as well as gold/gold hue abutment with metal coping. A reflectance spectrophotometer was used to evaluate the color difference between the implant cro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2011