Absorption of 193- and 213-nm laser wavelengths in sodium chloride solution and balanced salt solution.

نویسندگان

  • G T Dair
  • R A Ashman
  • R H Eikelboom
  • F Reinholz
  • P P van Saarloos
چکیده

OBJECTIVE To determine absorption coefficients for sodium chloride solution (saline) and balanced salt solution at the 193- and 213-nm laser wavelengths. METHODS Absorption coefficients were obtained for each of the component species found in balanced salt solution. This was achieved by measuring laser pulse transmission through solutions of varying concentration. The experiments were repeated using the 193-nm excimer and 213-nm solid-state laser wavelengths. Results for each species were then used to obtain an overall absorption coefficient and penetration depth for balanced salt solution and 0.9% sodium chloride solution. RESULTS Absorption coefficients in balanced salt solution for the 193- and 213-nm wavelengths were found to be 140 and 6.9 cm(-1), respectively. In 0.9% sodium chloride solution, the absorption coefficient was 81 cm(-1) at 193 nm and 0.05 cm(-1) at 213 nm. At 193 nm, absorption in balanced salt solution was dominated by sodium chloride. Sodium citrate emerged as the dominant species of absorption at 213 nm. CONCLUSIONS For the species investigated, we found reduced absorption for the longer wavelength of 213 nm. While the difference in wavelength between 193 and 213 nm is within about 10%, the respective molar absorption coefficients varied by 1 to 4 orders of magnitude. This indicates that predictions for the wavelength-dependent changes of absorption coefficients of other solutions are unreliable. CLINICAL RELEVANCE Fluid placed on the surface of the cornea during keratorefractive surgery has proved to be a barrier to ablation for the 193-nm wavelength. The increased penetration depth through sodium chloride solution and balanced salt solution for the longer 213-nm laser wavelength may mean that these solutions cannot be used as a masking agent for keratorefractive procedures performed with this wavelength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Faryab spring hydrochemistry in Hormozgan Province, Southern Iran

With a mean precipitation rate, much lower than that of the world, Iran is among the countries that face severe water challenges. The present study has dealt with the evaluation of hydrochemistry of Faryab spring water in Hormozgan Province, Iran. Four different composite water samples have been analyzed to detect major anions, cations, total dissolved solids, electrical conductivity, pH, and s...

متن کامل

Evaluation of Faryab spring hydrochemistry in Hormozgan Province, Southern Iran

With a mean precipitation rate, much lower than that of the world, Iran is among the countries that face severe water challenges. The present study has dealt with the evaluation of hydrochemistry of Faryab spring water in Hormozgan Province, Iran. Four different composite water samples have been analyzed to detect major anions, cations, total dissolved solids, electrical conductivity, pH, and s...

متن کامل

Hyperspectral temperature and salt dependencies of absorption by water and heavy water in the 400-750 nm spectral range.

The temperature and salt dependencies of absorption by liquid water (H2O) and heavy water (D2O) were determined using a hyperspectral absorption and attenuation meter (WET Labs, AC-S). Sodium chloride (NaCl) was used as a proxy for seawater salts. There was no significant temperature (PsiT) or salt (PsiS) dependency of absorption at wavelengths <550 nm. At wavelengths >550 nm, PsiT exhibited pe...

متن کامل

Laser Ablation Inductively Coupled Plasma

Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is one of the most successful direct solid sampling techniques for major, minor and trace element analysis. However, this technique still suffers from matrix dependent ablation characteristics, which makes quantification very difficult. Furthermore, the laser sampled material alters its composition from the sample to the de...

متن کامل

Dynamics of cavitation bubble induced by 193 nm ArF excimer laser in concentrated sodium chloride solutions

Cavitation bubbles were generated by the 193 nm argon fluoride excimer laser delivered with a specially designed tip into absorbing NaCl solution. The dynamics of bubble formation and collapse have been studied using fast flash photomicrography. The bubble dimensions were measured at different time delays as a function of the tip exit diameter, the energy fluence of the laser, and the NaCl conc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 119 4  شماره 

صفحات  -

تاریخ انتشار 2001