Simultaneous radiofrequency (RF) heating and magnetic resonance (MR) thermal mapping using an intravascular MR imaging/RF heating system.
نویسندگان
چکیده
Previous studies have confirmed the possibility of using an intravascular MR imaging guidewire (MRIG) as a heating source to enhance vascular gene transfection/expression. This motivated us to develop a new intravascular system that can perform MR imaging, radiofrequncy (RF) heating, and MR temperature monitoring simultaneously in an MR scanner. To validate this concept, a series of mathematical simulations of RF power loss along a 0.032-inch MRIG and RF energy spatial distribution were performed to determine the optimum RF heating frequency. Then, an RF generator/amplifier and a filter box were built. The possibility for simultaneous RF heating and MR thermal mapping of the system was confirmed in vitro using a phantom, and the obtained thermal mapping profile was compared with the simulated RF power distribution. Subsequently, the feasibility of simultaneous RF heating and temperature monitoring was successfully validated in vivo in the aorta of living rabbits. This MR imaging/RF heating system offers a potential tool for intravascular MR-mediated, RF-enhanced vascular gene therapy.
منابع مشابه
Radiofrequency energy-induced heating during MR procedures: a review.
During an MR procedure, most of the transmitted RF power is transformed into heat within the patient's tissue as a result of resistive losses. Not surprisingly, the primary bioeffects associated with the RF radiation used for MR procedures are directly related to the thermogenic qualities of this electromagnetic field. This review article discusses the characteristics of RF energy-induced heati...
متن کاملThermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz)
BACKGROUND Glioblastoma multiforme is the most common and most aggressive malign brain tumor. The 5-year survival rate after tumor resection and adjuvant chemoradiation is only 10 %, with almost all recurrences occurring in the initially treated site. Attempts to improve local control using a higher radiation dose were not successful so that alternative additive treatments are urgently needed. ...
متن کاملDetailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance Study
The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength sh...
متن کاملTemperature and perfusion monitoring during RF heating of the human calf muscle
Introduction One of the main concerns for patient safety in MR imaging is radiofrequency (RF) induced tissue heating. This heating arises from the intense RF exposure involved in MR imaging and the complex, spatially heterogeneous RF absorption in the human body. Recent simulation studies indicate that even within global SAR limitations in certain regions the local SAR levels and the resulting ...
متن کاملDependence of RF heating on SAR and implant position in a 1.5T MR system.
PURPOSE We evaluated radiofrequency (RF) heating of a humerus implant embedded in a gel phantom during magnetic resonance (MR) imaging for the specific absorption rate (SAR), angle between the implant and static magnetic field (B(0)), and position of the implant in the irradiation coil. METHODS We embedded a stainless steel humerus implant 2 cm deep in tissue-equivalent loop and mass phantoms...