Impedance Cardiography *
نویسندگان
چکیده
Objective: To evaluate the following: (1) the intramethod variability of impedance cardiography (ICG) cardiac output (CO) measurements via the latest generation monitor and thermodilution CO measurements (CO-TDs); (2) the intermethod comparison of ICG CO and CO-TD; and (3) comparisons of the intergeneration ICG CO equation to CO-TD, using the latest ICG CO equation, the ZMARC (CO-ICG), and the predecessor equations for measuring the ICG CO of Kubicek (CO-K), Sramek (CO-S), and Sramek-Bernstein (CO-SB). Design: Prospective study. Setting: A cardiovascular-thoracic surgery ICU in a community university-affiliated hospital. Patients: Post-coronary artery bypass graft patients (n 53) in whom 210 pairs of CO measurements were made. Interventions: None. Measurements and main results: The CO-ICG was determined simultaneously while the nurse was performing the CO-TD. Variability within the monitoring method was better for CO-ICG compared to CO-TD (6.3% vs 24.7%, respectively). The correlation, bias, and precision of the CO-ICG was good compared to CO-TD (r 0.658; r 0.811; bias, 0.17 L/min; precision, 1.09 L/min; CO-ICG 1.00 CO-TD 0.17; p < 0.001). A steady improvement in agreement of the previous ICG methodologies compared to CO-TD was observed as follows: (1) CO-K: r 0.309; r 0.556; bias, 1.71 L/min; precision, 1.81 L/min; CO-K 0.78 CO-TD 0.45; p < 0.001; (2) CO-S: r 0.361; r 0.601; bias, 1.46 L/min; precision, 1.63 L/min; COS 0.80 CO-TD 0.36; p < 0.001; and (3) CO-SB: r 0.469; r 0.685; bias, 0.77 L/min; precision, 1.69 L/min; CO-SB 1.03 CO-TD 0.95; p < 0.001. The CO-ICG demonstrated the closest agreement to CO-TD. Conclusion: The latest ICG technology for determining CO (CO-ICG) is less variable and more reproducible in an intrapatient sense than is CO-TD, it is equivalent to the average accepted CO-TD in post-coronary artery bypass graft patients, and showed marked improvement in agreement with CO-TD compared to measurements made using previous generation ICG CO equations. (CHEST 2003; 123:2028–2033)
منابع مشابه
Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: correlation between diurne- and position-challenged measurements
متن کامل
Assessment of the optimal atrioventricular delay in patients with dual chamber pacemakers using impedance cardiography and Doppler echocardiography
متن کامل
Impedance pneumography: noise as signal in impedance cardiography.
Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of "noise" in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band ...
متن کامل