A Smart Tool for Intraoperative Leg Length Targeting in Total Hip Arthroplasty: A Retrospective Cohort Study
نویسندگان
چکیده
BACKGROUND Leg length discrepancies following total hip arthroplasty (THA) may necessitate subsequent interventions, from heel lifts to revision surgery. Current intraoperative methods of determining leg length are either inaccurate or expensive and invasive. OBJECTIVE The objective of the current study was to investigate the ability of a novel, intraoperative smart tool (Intellijoint HIP®, Intellijoint Surgical®, Inc., Waterloo, ON) to provide accurate, real-time leg length measurements during THA. METHODS We retrospectively reviewed the medical records of 25 patients who underwent THA utilizing the Intellijoint HIP smart tool between February and August 2014. Intraoperative leg length data was compared with radiographic leg length calculations. Two observers blinded to the Intellijoint HIP findings independently assessed all post-procedure radiographs. RESULTS The mean difference between smart tool and radiographic measurements was 1.3 mm [CI: -0.1, 2.7]. 88% (22/25) of intraoperative measurements were within 5 mm of radiographic measurements; 100% (25/25) were within 10 mm. A Bland-Altman analysis showed excellent agreement, with 96% (24/25) of measurements within the statistical limit for acceptable agreement, and 84% (21/25) within the clinically acceptable range (± 5 mm). Removal of the first 13 procedures (surgeon training) decreased the mean difference between methods to 0.6 mm [-0.6, 1.9]. All post-training procedures were associated with a difference of <5 mm. There were no reported adverse events related to the use of the smart tool. CONCLUSION The Intellijoint HIP smart tool is a safe and accurate tool for providing intraoperative measurements of leg length in real-time.
منابع مشابه
Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty
Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...
متن کاملAn intraoperative device to restore femoral offset in total hip arthroplasty
BACKGROUND Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and posto...
متن کاملNovel method for ensuring leg length in total hip arthroplasty.
Despite the overwhelming clinical success of total hip arthroplasty, complications such as leg-length discrepancy can be a significant cause of functional impairment and patient dissatisfaction. Multiple intraoperative techniques are available for measuring femoral limb length; however, many require additional invasive hardware and those that do not are less accurate at measuring limb length. T...
متن کاملLeg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty
Despite concerted intraoperative attempts to establish equal limb alignment, leg length discrepancy (LLD) remains a frequent complication following elective total hip arthroplasty (THA) [1]. A number of effective intraoperative imaging and clinical limb length techniques have been recommended to minimize this complication; however, all of these assessment modalities have their reported limitati...
متن کاملAccurate Leg Length Measurement in Total Hip Arthroplasty: A Comparison of Computer Navigation and a Simple Manual Measurement Device
BACKGROUND Several studies have shown that better placement of the acetabular cup and femoral stem can be achieved in total hip arthroplasty (THA) by using the computer navigation system rather than the free-hand alignment methods. However, there have been no comparisons of the relevant clinical advantages in using the computer navigation as opposed to the manual intraoperative measurement devi...