Lessons from the Tc-99m shortage: implications of substituting Tl-201 for Tc-99m single-photon emission computed tomography.

نویسندگان

  • Gary R Small
  • Terrence D Ruddy
  • Oana Simion
  • Mohammed Alam
  • Lyanne Fuller
  • Li Chen
  • Rob S Beanlands
  • Benjamin J W Chow
چکیده

BACKGROUND In 2009, the Chalk River nuclear reactor closed for repairs that led to a critical shortage of technetium-99m (Tc-99m). Several centers used thallium-201 (Tl-201) as an alternative radiotracer for myocardial perfusion imaging. Because Tl-201 is considered by many as a suboptimal radiotracer, we sought to understand the impact of using Tl-201 (during the Tc-99m shortage) on downstream resource utilization. METHODS AND RESULTS We performed a retrospective study at the Ottawa Heart Institute of 7402 patients (60% men; mean age, 62.6 ± 11.8 years), patients were referred for myocardial perfusion imaging between May 2008 and January 2011 (PRE_Tc-99m [2938 patients]), during (DURING_Tl-201 [2959 patients]), and after (POST_Tc-99m [1505 patients]) the Tc-99m shortage. Patients were followed for 6 months after their index myocardial perfusion imaging to determine subsequent rates of cardiac catheterization or noninvasive imaging. More downstream testing was seen in the Tl-201 cohort (639 [21.4%] patients) than the Tc-99m cohort (537 [12.1%] patients; P<0.001). After adjustment using propensity scores, differences in downstream referral rates were maintained. The downstream investigations resulted in an estimated increase in per-patient costs ($165.22; 95% confidence interval, 153.00-177.42) in the DURING_Tl-201 cohort compared with the Tc-99m cohort ($90.97; 95% confidence interval, 83.42-98.90; P<0.001). As well, the mean effective radiation dose per-patient was higher in DURING_Tl-201 (23.57 mSv; 95% confidence interval, 23.16-23.96) than in Tc-99m (12.92 mSv; 95% confidence interval, 12.55-13.40; P<0.001). CONCLUSIONS In this single-center study, the use of Tl-201 during the Tc-99m shortage was associated with an increase in downstream testing, cost, and patient radiation exposure, but these findings may not be generalizable to other centers. Although Tl-201 provided a short-term solution to the unexpected Tc-99m shortage, long-term cost-effective solutions should be areas of future study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

OBJECTIVES The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. BACKGROUND The clinical application of vasodilator stress for perfusion imaging requires consider...

متن کامل

Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease.

OBJECTIVES We compared dipyridamole technetium-99m (Tc-99m) tetrofosmin and thallium-201 (Tl-201) single-photon emission computed tomographic (SPECT) imaging with respect to the detection rate of perfusion abnormalities in 26 patients with angiographic coronary artery disease (CAD). BACKGROUND Experimental studies have shown that myocardial extraction of Tc-99m tetrofosmin is lower than that ...

متن کامل

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

Detection of occult thymoma during exercise thallium 201, technetium 99m tetrofosmin imaging for coronary artery disease.

Thallium (Tl) 201 and technetium (Tc) 99m tetrofosmin single-photon emission CT are routinely used in the evaluation of coronary artery disease. Mediastinal tumors demonstrate Tl 201 and Tc 99m tetrofosmin uptake. We report a 56-year-old man who developed chest pain after a previously successful angioplasty and stent of the left anterior descending coronary artery. He underwent a Tl 201, Tc 99m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2013