Comparison of the Cosmed K4b2 Portable Metabolic System in Measuring Steady-State Walking Energy Expenditure
نویسندگان
چکیده
BACKGROUND AND AIMS Recent introduction of the Cosmed K4b(2) portable metabolic analyzer allows measurement of oxygen consumption outside of a laboratory setting in more typical clinical or household environments and thus may be used to obtain information on the metabolic costs of specific daily life activities. The purpose of this study was to assess the accuracy of the Cosmed K4b(2) portable metabolic analyzer against a traditional, stationary gas exchange system (the Medgraphics D-Series) during steady-state, submaximal walking exercise. METHODS Nineteen men and women (9 women, 10 men) with an average age of 39.8 years (+/-13.8) completed two 400 meter walk tests using the two systems at a constant, self-selected pace on a treadmill. Average oxygen consumption (VO2) and carbon dioxide production (VCO2) from each walk were compared. RESULTS Intraclass Correlation Coefficient (ICC) and Pearson correlation coefficients between the two systems for weight indexed VO2 (ml/kg/min), total VO2 (ml/min), and VCO2 (ml/min) ranged from 0.93 to 0.97. Comparison of the average values obtained using the Cosmed K4b(2) and Medgraphics systems using paired t-tests indicate no significant difference for VO2 (ml/kg/min) overall (p = 0.25), or when stratified by sex (p = 0.21 women, p = 0.69 men). The mean difference between analyzers was - 0.296 ml/kg/min (+/-0.26). Results were not significantly different for VO(2) (ml/min) or VCO2) (ml/min) within the study population (p = 0.16 and p = 0.08, respectively), or when stratified by sex (VO(2): p = 0.51 women, p = 0.16 men; VCO2: p = .11 women, p = 0.53 men). CONCLUSION The Cosmed K4b(2) portable metabolic analyzer provides measures of VO2 and VCO2 during steady-state, submaximal exercise similar to a traditional, stationary gas exchange system.
منابع مشابه
Test-retest reliability of a portable gas analysis system under free living conditions.
INTRODUCTION K4b2 (COSMED Srl Italy) is a portable device that is considered valid and reliable for measuring oxygen uptake (VO2) and carbon dioxide production (VCO2) under laboratory conditions. OBJECTIVES Evaluate the test-retest reliability of K4b2 during walking, stair climbing and descending stairs under free living conditions. METHODS Twelve participants completed two self-selected co...
متن کاملEnergy cost of exergaming: a comparison of the energy cost of 6 forms of exergaming.
OBJECTIVE To determine the relative effect of interactive digital exercise that features player movement (ie, exergames) on energy expenditure among children of various body mass indexes (BMIs; calculated as weight in kilograms divided by height in meters squared). DESIGN Comparison study. SETTING GoKids Boston, a youth fitness research and training center located at University of Massachus...
متن کاملQuantification of energy expenditure during gait in children affected by cerebral palsy.
AIM Children affected by cerebral palsy (CP) are generally characterised by some movement limitations and abnormalities that compromised gait pattern. These disabilities during deambulation may lead to excessive energy cost and so to a compromised energy efficiency. METHODS In this study oxygen expenditure was evaluated during walking in 20 children affected by CP and in 20 healthy children, ...
متن کاملValidity of estimating minute-by-minute energy expenditure of continuous walking bouts by accelerometry
BACKGROUND Objective measurement of physical activity remains an important challenge. For wearable monitors such as accelerometer-based physical activity monitors, more accurate methods are needed to convert activity counts into energy expenditure (EE). PURPOSE The purpose of this study was to examine the accuracy of the refined Crouter 2-Regression Model (C2RM) for estimating EE during the t...
متن کاملThe metabolic equivalents of one-mile walking by older adults; implications for health promotion
Background: Instructions for older adults regarding the intensity of walking may not elicit an intensity to infer health gains. We recorded the metabolic equivalents (METs) during a 1-mile walk using constant and predicted values of resting MET in older adults to establish walking guidelines for health promotion and participation. Methods: In a cross-sectional design study, participants (15 men...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -