Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement – A finite element analysis

نویسندگان

  • Philippe Moewis
  • Sara Checa
  • Ines Kutzner
  • Hagen Hommel
  • Georg N Duda
چکیده

Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Staphylococcus aureus Colonization in Patients Undergoing Total Hip or Knee Arthroplasty and Costeffectiveness of Decolonization Programme

Background: Periprosthetic joint infection is a devastating complication of total joint arthroplasty. It seems that thepatient’s skin, nose, throat, and urine are important sites for microbial colonization. Colonization with staphylococcusaureus, especially methicillin resistant increases the risk of periprosthetic joint infection. The aim of this study was toassess the prevalence of staphyloco...

متن کامل

Cementless meniscal bearing knee arthroplasty: 7- to 12-year outcome analysis.

1. Rotational mobility of a widely used rotating platform total knee replacement. Iowa Orthop J, 2001. 21: p. 90. 2. Multi-contact-surface finite element model of a widely used rotating platform total knee. Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee.Unicompartmental "Lotus" knee prosthesis. Analysis of the results of a series of 142 ...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

BACKGROUND Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018