In Situ Thermistor Calibration for Improved Measurement of Soil Temperature Gradients

نویسندگان

  • Dilia Kool
  • Joshua L. Heitman
  • Naftali Lazarovitch
  • Nurit Agam
چکیده

Accurate measurement of soil temperature gradients is important for the estimation of soil heat flux and latent heat flux, both major components of the surface energy balance. Soil temperature gradients are commonly measured using heat-pulse sensors equipped with thermistors. In this study, individual thermistors showed absolute temperature differences on the order of 0.2°C when placed under uniform temperature conditions. These differences compromised measurement of soil temperature gradients over small depth increments and/or conditions with relatively minor variation in temperatures. An in situ calibration approach was found to reduce the uncertainty between thermistors to about 0.05°C in a vineyard under arid conditions. In situ calibration results were similar to laboratory results before and after field deployment for temperatures ranging between 4 and 60°C. Thermistor offsets were found to change very little over a 5-yr period, indicating that preor post-laboratory calibration could be sufficient. The in situ approach can be useful when calibration prior to field deployment is unavailable and/or sensor failure prevents post-field calibration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

Micro-PCR Chip NTC-Thermistor Sensor-Calibration System

In this paper, we implement a Steinhart-Hart calibration-factor value measurement system to obtain accurate temperature measurements of a negative-temperature coefficient thermistor. The thermistor is mounted on a micro-polymerase chain reaction (PCR) chip in a micro-PCR systemthat requires accurate temperature measurement and control. When obtaining the calibration-factor value, it is impossib...

متن کامل

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Calibration of Buffer-less system for thermistor temperature measurement

This paper presents a temperature measurement system without the input buffer. A voltage follower or a buffer is required to minimize the influence of the ADC input impedance in the thermistor temperature measurement system. In such system, a high performance operational amplifier is usually required to prevent the noise and distortion due to the additional circuit. Negative power is also neces...

متن کامل

Temperature gradients in the rabbit eye.

Measurements of the temperature of the various parts of the rabbit eye under both local and general Nembutal anesthesia were made ivith the thermistor as the temperature-measuring device at a room temperature of 22 to 24° C, and a relative humidity of 33 to 53 per cent. The equipment and its calibration are described in detail. The existence of a temperature difference of 6° C. (corrected for t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016