Evaluation of an enzyme immunoassay for determining diazepam and nordiazepam in serum and urine.

نویسندگان

  • J E Wallace
  • S C Harris
  • E L Shimek
چکیده

We evaluated a commercially available enzyme immunoassay method for determining the concentration of total diazepam plus its active metabolite, nordiazepam, in small amounts of serum and urine. The coefficients of variation were 5% within assay and 8% between assay. Concentrations so measured for patients' sera correlated well with those obtained both by gas chromatography with electron-capture detection and by liquid chromatography with ultraviolet detection. For urine samples, the correlation between values obtained by the enzyme immunoassay method and those for total diazepam/nordiazepam/oxazepam obtained by liquid chromatography was adequate for routine clinical toxicological use. The ability of the immunoassay to determine other benzodiazepines was also evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benzodiazepines: toxic serum concentrations in positive enzyme immunoassay responses.

A total of 588 blood specimens collected in an emergency unit were screened for benzodiazepines (BZDs) using enzyme-multiplied immunoassay and gas chromatography. Two-hundred eighty-five samples were positive for BZDs, and 303 samples that were negative by EMIT included 20 samples with BZDs detectable by gas-liquid chromatography. A total of 15 BZDs were identified, and the most frequently occu...

متن کامل

Analysis for diazepam and nordiazepam by electron-capture gas chromatography and by liquid chromatography.

We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.), resulted in improved chromatographic sensitivity and peak symmetry for the two benzodia...

متن کامل

DETERMINATION OF SERUM CORTISOL LEVEL BY A DIREC T ENZYME IMMUNOASSAY USING PENICILLINASE AS LABEL

Serum cortisol level was measured by an enzyme immunoassay (EIA) using the enzyme penicillinase as a label without prior extraction and purification. Polyclonal antibodies were raised against cortisol-3-ortho-carboxymethyl-oxime (cortisol-3-0-CMO) conjugated to bovine serum albumin (BSA). This antibody showed a very low cross-reactivity with structurally related steroids (3.7% for corticos...

متن کامل

Papain: a novel urine adulterant.

The estimated number of employees in the United Stated screened annually for illicit drugs is approximately 20 million, with marijuana being the most frequently abused drug. Urine adulterants provide an opportunity for illicit drug users to obtain a false-negative result on commonly used primary drug screening methods such as the enzyme multiplied immunoassay technique and the fluorescence pola...

متن کامل

DEMONSTRATION OF LOCAL ANTITOXOPLASMIC IMMUNOGLOBULIN G PRODUCTION IN OCULAR TOXOPLASMOSIS, TRACED BY ENZYME IMMUNOASSAY OF AQUEOUS HUMOR AND SERUM

Forty patients with cataracts, as well as 40 patients with proven ocular toxoplasmosis were enrolled in this prospective clinical study. Serum IgG and aqueous IgG in both groups were measured by enzyme-linked immunosorbent assay (ELISA) and the corresponding ratios were calculated. Serum IgG/aqueous humor IgG ratio was less than 100 in the patient group and more than 100 in the control gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 13  شماره 

صفحات  -

تاریخ انتشار 1980