Imaging by using proton-induced quasi- monochromatic X-ray emission

نویسندگان

  • Ikuo Kanno
  • Ryo Imamura
  • S. Iwatani
  • J. Kaneko
  • J. Hasegawa
  • H. Fukuda
  • R. He
  • Y. Saitoh
  • T. Sakai
  • M. Ogawa
  • Y. Oguri
چکیده

Quasi-monochromatic X-ray emission induced by MeV-proton bombardment onto metallic targets was applied to radiography of small samples. The X-ray energy was adjusted in the range of z4–23 keV by changing the target material. The radiograms were recorded on an imaging plate. A small phantom made of Lucite was prepared for the test of photography using a contrast medium (RuCl3$H2O; ruthenium chloride). To clearly observe the image of the contrast agent, the photon energy was chosen to be 23.17 keV (Cd Ka) which is slightly above the K-absorption edge of Ru at 22.12 keV. Only the image of the contrast agent was successfully extracted by subtracting the image taken by 21.18-keV X-rays (Pd Ka) from that obtained by the 23.17-keV photons. Also images of a small fish sample were taken using a point-like X-ray source excited by a proton microbeam with a diameter of z10 mm. In this experiment, the X-ray energy was adjusted to 4.51 keV (Ti Ka) to obtain a strong attenuation by Ca in the bones. A fine structure of the bones in the thin caudal fin (!100 mm) was highly contrasted by this method. The spatial resolution of the picture was z20 mm. Performance of the above technique based on the proton-induced quasimonochromatic X-ray emission is discussed in comparison to conventional methods. q 2004 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins

Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Reconstruction of Quasi-Monochromatic Images for Multispectral X-ray Imaging with a Pinhole Array and a Flat Bragg Mirror

We have developed a software package for reconstruction of quasi-monochromatic images from a multiple monochromatic x-ray imager for inertial confinement fusion implosions. The instrument consists of a pinhole array, a multi-layer Bragg mirror, and a image detector. The pinhole array projects hundreds of images onto the detector after reflection off the multi-layer Bragg mirror, which introduce...

متن کامل

Investigation of heavy trace elements in neoplastic and non-neoplastic human thyroid tissue: A study by proton-induced X-ray emissions.

Background: Within the context of developing techniques to facilitate the diagnosis of the thyroid diseases, the elemental composition of pathological thyroid tissue (neoplastic and non-neoplastic) was investigated by proton induced X-ray emission. The PIXE has been widely used as a sensitive technique for trace elemental analysis in both biological and medical fields. Materials and Methods: Th...

متن کامل

Quasi-monochromatic field-emission x-ray source.

By favoring the L-peak emission over the bremsstrahlung part, direct quasi-monochromatic soft x-ray emission has been obtained with a field emission (FE) x-ray source. The electron impact x-ray setup uses an arrayed cathode of carbon nanopearl FE tips as a stable cold electron source within a vacuum of 10(-6)-10(-7) Torr. The high brightness of the FE e-beam coupled with the array structure of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004