Percutaneous transcatheter valve-in-valve implantation in stenosed tricuspid valve bioprosthesis.

نویسندگان

  • Leen A F M Van Garsse
  • Rachel M A Ter Bekke
  • Vincent G V A van Ommen
چکیده

Transcatheter valve-in-valve implantation is a promising treatment option for degenerated bioprosthetic heart valves in high-risk patients.1 Successful percutaneous techniques have been described for pulmonary and aortic valves.2,3 We present the first successful percutaneous tricuspid valve-in-valve implantation. The patient was a fragile 74-year-old woman with chronic obstructive pulmonary disease (forced expiratory volume in 1 second, 53%), impaired renal function (modified diet in renal disease 35 mL/min/1.73 m), and cardiac hepatic cirrhosis with ascites and cachexia (body mass index 19 kg/m), admitted with chronic right-sided heart failure and severe stenosis of a degenerated tricuspid bioprosthesis. Previously, a partial atrioventricular canal defect had been treated in 3 consecutive surgical interventions. During the last procedure, 23 years ago, a mechanical mitral valve replacement (St. Jude 25 mm, SJM, Inc., St. Paul, MN) had been performed, combined with a bioprosthetic tricuspid valve replacement (pericardial Carpentier Edwards 25 mm, Edwards Lifesciences, Irvine, CA). Transthoracic echocardiography and live 3D imaging revealed normal left ventricular systolic function with acceptable function of the mitral valve prosthesis, dilated left atrium (278 mL), right ventricle and right atrium (103 mL), with diminished right ventricular function (TAPSE 11 mm), and a severely calcified and stenosed tricuspid valve with maximal and mean gradients of 18 and 11 mm Hg, respectively (Figure 1 and 4, Movie 1). Due to poor hemodynamic parameters, inotropes were being administered preoperatively, and a semiurgent percutaneous procedure was performed. Cannulae for cardiopulmonary bypass were percutaneously placed via the right femoral vessels under local anesthesia, and a pacemaker wire was positioned in the left ventricle via the left femoral artery. Transoesophageal echocardiographic visualization of the tricuspid bioprosthesis was hampered by scatter of the mechanical mitral valve. Alternatively, an intracardiac echocardiography probe (AcuNavTM, Biosense Webster, Diamond Bar, CA) was inserted via the left femoral vein into the right atrium, rendering adequate peroperative imaging. Once stable hemodynamic condition was achieved, general anesthesia was started. A 22 Fr sheath was introduced via the right internal jugular vein. The steerable Edwards Retroflex balloon system permitted crossing of the tricuspid stenosed orifice over a curved guide wire (Cordis standard exchange J-tip, 0.035 inch) situated in the right ventricular apex. Valvuloplasty (balloon inflated to 22 mm) was performed under rapid ventricular pacing; concomitant contrast injection in the right atrium, during brief cardiopulmonary bypass interruption, confirmed complete occlusion of the orifice area. A 23 mm Edwards Sapien valve was crimped on the Retroflex delivery balloon system (Movie 2) and successfully implanted into the degenerated bioprosthesis (Figure 2 A-E, Movie 3). Intracardiac echocardiography and 3D transthoracic echocardiography confirmed adequate position and excellent function of the tricuspid bioprosthetic valve (Figure 3 and 4, Movies 4 and 5), with maximal gradient 5 (mean 2) mm Hg with trivial ( grade I) regurgitation. After 3 days Figure 1. Live 3D transthoracic echocardiography showing severely calcified and stenotic bioprosthetic tricuspid valve, ventricular view. A, Interventricular septum. B, Right ventricular free wall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.

The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a ...

متن کامل

Balloon dilatation of a stenosed bioprosthesis in the tricuspid valve position.

Percutaneous balloon dilatation of a stenosed Ionescu-Shiley bioprosthesis in the tricuspid valve position was performed twice in a 19 year old woman. On each occasion there was a considerable improvement in symptoms and haemodynamic function but the effect lasted for only a few months. When the valve was excised it showed no evidence of the previous balloon dilatations.

متن کامل

Emergent Chimney Stent to Treat Left Main Occlusion Following Valve-In-Valve Transfemoral Aortic Implantation Chimney Stent Following Valve-In-Valve TAVI

Implantation of transcatheter valves inside degenerated surgical bioprosthesis is nowadays a very good alternative to redo a new cardiac surgery especially in high risk patients. Although procedural success is achieved in most of the patients, these procedures are associated with few potential risks such as coronary occlusion. It is very important to perform an exhaustive study prior to the val...

متن کامل

Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis

Introduction Transcatheter implantation of balloon expandable valves in high-risk patients with degenerated tricuspid bioprostheses has been reported since 2010 [1, 2]. Although there have been cases where the SAPIEN valve was implanted in the tricuspid position without rapid pacing [3, 4], invasive rapid ventricular pacing is usually applied during valve deployment. We present a case report do...

متن کامل

Percutaneous tricuspid valve replacement for a stenosed bioprosthesis.

Percutaneous replacement of the aortic and pulmonic valves has rapidly gained acceptance in clinical practice as a feasible alternative to open valve surgery in patients deemed to be at high operative risk.1,2 Total percutaneous tricuspid valve replacement (TVR), on the other hand, has not yet been documented in humans, although this approach has been described in experimental animals.3 Webb et...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 123 5  شماره 

صفحات  -

تاریخ انتشار 2011