Effect of upper arm cuff pressure on pulse morphology using photoplethysmography.

نویسندگان

  • L Suganthi
  • M Manivannan
چکیده

Study of Arterial pressure and flow variation when external pressure applied is critical in understanding clinical relevance of pulse. We propose a distributed model of entire human arterial tree to describe the hemodynamic changes due to pressure applied on the brachial artery. Input to this distributed model is from a four element Windkessel model. We measured the blood volume during brachial occlusion in six healthy subjects using finger photoplethysmography (PPG). We analyzed the morphological changes in both the model and the experiment. We found that both the model pressure pulse and the finger volume pulse morphology changing with the applied pressure. We calculated the normalized values of pulse height, maximum systolic slope, maximum diastolic slope and peak to peak interval (PPI) for each beat. Mean values of all the morphological parameters show an initial rise and in the model the maximum occurs at 60-80mmHg while in the experiments it occurs at 40mmHg. The predicted model parameters are positively correlated with measured parameters (for maximum systolic slope r = 0.54; for maximum diastolic slope r = 0.77; for pulse height r = 0.89 when P < 0.05). The PPI variation is different for each subject reflecting the reflex properties of the individual. Variable elastance and reflex system should be incorporated in the model to accurately predict the experimental results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVESTIGATION OF PHOTOPLETHYSMMOGRAPHIC SIGNALS AND ARTERIAL BLOOD OXYGEN SATURATION VALUES (SpO2) DURING BLOOD PRESSURE CUFF-INDUCED HYPOPERFUSION

Photoplethysmography is a non-invasive electro-optical technique widely used in the study and monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. Photoplethysmography is used in the estimation of arterial oxygen saturation (SpO2) by pulse oximetry. A reflectance finger photoplethysmographic (PPG) probe and a multiplexed data acquisition system oper...

متن کامل

Pilot investigation of photoplethysmographic signals and blood oxygen saturation values during blood pressure cuff-induced hypoperfusion

Photoplethysmography (PPG) is a non-invasive electro-optical technique widely used in the monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. The technique is based on the absorption properties of vascular tissue when it is transilluminated by light. Photoplethysmography is also used in the estimation of arterial blood oxygen saturation ðSpO2Þ by p...

متن کامل

Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia

Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...

متن کامل

Evaluation of vascular wall elasticity of human digital arteries using alternating current-signal photoplethysmography

PURPOSE A simple method of estimating arterial elasticity in the human finger using a volume-oscillometric technique with photoplethysmography was principally studied under the various effects of age, sex, and cold-stress stimulation for testing the capability of using this technique in arterial elasticity analysis. METHODS Amplitude variations in the alternating current signal of the photopl...

متن کامل

Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study

BACKGROUND Blood pressure is a critical bio-signal and its importance has been increased with the aged society and the growth of cardiovascular disease population. However, most of hypertensive patients have been suffered the inconvenience in monitoring blood pressure in daily life because the measurement of the blood pressure depends on the cuff-based technique. Nowadays there are many trials ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference

دوره 2009  شماره 

صفحات  -

تاریخ انتشار 2009