Implementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions

نویسندگان

  • Edgardo Doerner
  • Paola Caprile
چکیده

The shape of the radiation source of a linac has a direct impact on the delivered dose distributions, especially in the case of small radiation fields. Traditionally, a single Gaussian source model is used to describe the electron beam hitting the target, although different studies have shown that the shape of the electron source can be better described by a mixed distribution consisting of two Gaussian components. Therefore, this study presents the implementation of a double Gaussian source model into the BEAMnrc Monte Carlo code. The impact of the double Gaussian source model for a 6 MV beam is assessed through the comparison of different dosimetric parameters calculated using a single Gaussian source, previously com-missioned, the new double Gaussian source model and measurements, performed with a diode detector in a water phantom. It was found that the new source can be easily implemented into the BEAMnrc code and that it improves the agreement between measurements and simulations for small radiation fields. The impact of the change in source shape becomes less important as the field size increases and for increasing distance of the collimators to the source, as expected. In particular, for radiation fields delivered using stereotactic collimators located at a distance of 59 cm from the source, it was found that the effect of the double Gaussian source on the calculated dose distributions is negligible, even for radiation fields smaller than 5 mm in diameter. Accurate determination of the shape of the radiation source allows us to improve the Monte Carlo modeling of the linac, especially for treatment modalities such as IMRT, were the radiation beams used could be very narrow, becoming more sensitive to the shape of the source.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

متن کامل

Comparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams

Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study

Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The lina...

متن کامل

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016