Improved Iterative Calibration for Triaxial Accelerometers Based on the Optimal Observation

نویسندگان

  • Jie Yang
  • Wenqi Wu
  • Yuanxin Wu
  • Junxiang Lian
چکیده

This paper presents an improved iterative nonlinear calibration method in the gravitational field for both low-grade and high-grade triaxial accelerometers. This calibration method assumes the probability density function of a Gaussian distribution for the raw outputs of triaxial accelerometers. A nonlinear criterion function is derived as the maximum likelihood estimation for the calibration parameters and inclination vectors, which is solved by the iterative estimation. First, the calibration parameters, including the scale factors, misalignments, biases and squared coefficients are estimated by the linear least squares method according to the multi-position raw outputs of triaxial accelerometers and the initial inclination vectors. Second, the sequence quadric program method is utilized to solve the nonlinear constrained optimization to update the inclination vectors according to the estimated calibration parameters and raw outputs of the triaxial accelerometers. The initial inclination vectors are supplied by normalizing raw outputs of triaxial accelerometers at different positions without any a priori knowledge. To overcome the imperfections of models, the optimal observation scheme is designed according to some maximum sensitivity principle. Simulation and experiments show good estimation accuracy for calibration parameters and inclination vectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Placement of Triaxial Accelerometers for Modal Vibration Tests

Proper pretest planning is a vital component of any successful vibration test. An extremely important part of the pretest exercise is the placement of sensors, usually in the form of accelerometers. The accelerometers must be placed such that all of the important dynamic information is obtained during the course of the test. The resulting sensor configuration must be optimal in some sense such ...

متن کامل

Review and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector

Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...

متن کامل

Validation of uniaxial and triaxial accelerometers for the assessment of physical activity in preschool children.

PURPOSE Given the unique physical activity (PA) patterns of preschoolers, wearable electronic devices for quantitative assessment of physical activity require validation in this population. Study objective was to validate uniaxial and triaxial accelerometers in preschoolers. METHODS Room calorimetry was performed over 3 hours in 64 preschoolers, wearing Actical, Actiheart, and RT3 acceleromet...

متن کامل

Kinematic Caiibration by Means of a Triaxial Accelerometer

A new method for kinematic calibration of a robot zs presented, based on triaxial measurement of acceleration by a sensor fixed to the robot end-point. The kinematic parameters are evaluated by means of a series of simple tests ( two for each jo in t ) . In these tests each jo in t , except the one under consideration, is kept fired. Acceleration and encoder output are then acquired. Simulation...

متن کامل

A Novel System-Level Calibration Method for Gimballed Platform IMU Using Optimal Estimation

An accurate calibration of inertial measurement unit errors is increasingly important as the inertial navigation system requirements become more stringent. Developing calibration methods that use as less as possible of IMU signals has 6-DOF gimballed IMU in space-stabilized mode is presented. It is considered as held stationary in the test location incorporating 15 di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012