STUDY DESIGN A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. OBJECTIVE To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. SUMMARY OF BACKGROUND DATA The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. METHODS A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). RESULTS A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. CONCLUSION Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and reevaluation of postoperative low-dose CT imaging. LEVEL OF EVIDENCE 3.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device

BACKGROUND Pedicle screw insertions are commonly used for posterior fixation to treat various spine disorders. However, the misplacement of pedicle screws can lead to disastrous complications. Inaccurate pedicle screw placement is relatively common even when placement is performed under fluoroscopic control. In order to improve the accuracy of the screw placement, we applied a technique using g...

متن کامل

The rate of screw misplacement in segmental pedicle screw fixation in adolescent idiopathic scoliosis

BACKGROUND AND PURPOSE There are no reports in the literature on the influence of learning on the pedicle screw insertion. We studied the effect of learning on the rate of screw misplacement in patients with adolescent idiopathic scoliosis treated with segmental pedicle screw fixation. METHOD We retrospectively evaluated low-dose spine computed tomography of 116 consecutive patients (aged 16 ...

متن کامل

Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.

STUDY DESIGN Prospective clinical study with postoperative radiologic control of pedicle screw placement in the cervical spine. OBJECTIVES To evaluate whether cervical pedicle screws can be placed safely in a conventional technique when using cannulated screws and separate stab incisions. Also, to evaluate if accuracy and safety of pedicle screw placement can be improved using a computer-assi...

متن کامل

Intraoperative biomechanics of lumbar pedicle screw loosening following successful arthrodesis.

Pedicle screw loosening has been implicated in recurrent back pain after lumbar spinal fusion, but the degree of loosening has not been systematically quantified in patients. Instrumentation removal is an option for patients with successful arthrodesis, but remains controversial. Here, we quantified pedicle screw loosening by measuring screw insertion and/or removal torque at high statistical p...

متن کامل

Accuracy of pedicle screw placement in thoracolumbar spine with conventional open technique.

AIM To demonstrate the incidence of screw misplacement and revision rates in a group of 72 patients that underwent pedicle screw fixation for spinal pathologies using the conventional, fluoroscopy-guided open technique. MATERIAL AND METHODS Data from 72 consecutive patients with spinal instability that received 472 screws between April 2011 and May 2013 were reviewed and pedicle wall breach w...