Liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometric imaging with sprayed matrix for improved sensitivity, reproducibility and quantitation.

نویسندگان

  • Zichuan Zhang
  • Jun Kuang
  • Lingjun Li
چکیده

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging (MSI) has been employed as a detection method for both capillary electrophoresis (CE)-MALDI and liquid chromatography (LC)-MALDI analyses. Based on our previous studies, here we report a new interface to couple LC with MSI by employing an automated matrix sprayer. The LC trace is directly collected on a ground stainless steel MALDI plate and dried. The matrix is sprayed on the MALDI plate using a programmable matrix sprayer. With the highly uniform matrix layers produced from the sprayer, the MS image signal quality is significantly improved with enhanced signal-to-noise ratios for analyte peaks. With the programmable matrix application and imaging MS data acquisition, the new LC-MSI platform exhibits highly stable and reproducible performance. A total of 87 bovine serum albumin (BSA) tryptic peptides and 295 putative neuropeptides from blue crab pericardial organs have been observed with LC-MSI analysis, exhibiting better performance in terms of peptide coverage than regular LC-MALDI with discrete spot collection and our previously reported LC-MSI interface with the matrix being delivered by a capillary. In addition to relative quantitation with isotopic labeling as we have previously demonstrated, we performed the first absolute quantitation using the new LC-MSI platform and obtained accurate quantitation results for neuropeptides, indicating great potential for quantitative analysis of complex samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Desorption Electrospray Ionization (DESI)

A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The resulting mass spectra are similar to normal ESI mass ...

متن کامل

On-chip solid-phase extraction pre-concentration/focusing substrates coupled to atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry for high sensitivity biomolecule analysis.

Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP-MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP-MALDI suffers from less-than-optimal sensitivity due to ion losses during transport fr...

متن کامل

Application of Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry

The clarification of metabolic dynamics in lesion areas is important. Many approaches, such as high performance liquid chromatography mass spectrometry, gas chromatography mass spectrometry, immunohistochemistry, are used to define disease-related abnormalities. Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) is attracting attention as a new valuable tool. MALD...

متن کامل

Trace determination of glycols by HPLC with UV and electrospray ionization mass spectrometric detections.

A high-performance liquid chromatography/mass spectrometry (HPLC/MS) method is developed for trace determination of glycols (ethylene glycol, 1,2- and 1,3-propylene glycols, and 2,3-butylene glycol) in water after derivatization with benzoyl chloride. Benzoyl esters of glycols are separated by microcolumn reversed-phase HPLC. Sensitivity and linearity of UV detection at 237 nm is compared with ...

متن کامل

Matrix-assisted laser desorption ionization--time of flight mass spectrometry of lipopeptide biosurfactants in whole cells and culture filtrates of Bacillus subtilis C-1 isolated from petroleum sludge.

An innovative method was developed for rapid sensitive detection and efficient structural characterization of lipopeptide biosurfactants by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry by using whole microbial cells and crude culture filtrates as targets in combination with surface tension measurements. This was done for a bacterial strain that was is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 138 21  شماره 

صفحات  -

تاریخ انتشار 2013