Development and evaluation of VIE-PNN, a knowledge-based system for calculating the parenteral nutrition of newborn infants
نویسندگان
چکیده
Calculating the daily changing composition of parenteral nutrition for small newborn infants is troublesome and time consuming routine work in neonatal intensive care. The task needs expertise and experience and is prone to inherent calculation errors. We designed VIE-PNN (Vienna Expert System for Parenteral Nutrition of Neonates), a knowledge-based system (KBS) in order to reduce daily routine work and calculation errors. VIE-PNN was redesigned several times because the clinicians accepted the system only when it saved time. The most recent version of VIE-PNN uses an Hypertext Markup Language (HTML)-based client-server architecture and is integrated into the intranet of the local patient data management system. Since more than 3 years all parenteral nutrition plans are calculated using VIE-PNN. Evaluating the system's performance and the users contentedness, we compared 50 nutrition plans calculated in parallel using VIE-PNN or a hand-held calculator, retrospectively analyzed more than 5000 nutrition plans stored in VIE-PNNs database and evaluated a user questionnaire. Nutrition plans were calculated in a mean time of 2.4 versus 7.1min using VIE-PNN or the hand-held calculator. Errors and omissions in the nutrition plans were detected in 22% versus 56% and errors in the VIE-PNN's plans occurring only with interactively changed values. Reviews of stored plans show that a mean of 4 out of 16 parameters were interactively changed. VIE-PNN was well accepted. Most important reasons for the successful operation of VIE-PNN in the daily routine work were time savings and robustness of the system.
منابع مشابه
Benefits of a Knowledge-based System for Parenteral Nutrition Support: a Report after 5 Years of Routine Daily Use
Calculating the daily changing composition of parenteral nutrition for small newborn infants is troublesome and time consuming routine work in neonatal intensive care. The task needs expertise and experience and is prone to inherent calculation errors. In 1996 we introduced a knowledge-based system called VIE-PNN at the neonatal intensive care unit (NICU). It supports the daily calculation of n...
متن کاملVIE-PNN - An Expert System for Parenteral Nutrition of Neonates
The planning of an adequate nutritional support for meeting the metabolic requirements of sick neonates is a tedious time consuming calculation, needs practical expert knowledge and involves the risk of introducing possibly fatal errors. We therefore developed the interactive support system VIE–PNN for calculating the composition of parenteral nutrition solutions (PNS) for neonates at intensive...
متن کاملVie – Pnn
The planning of an adequate nutritional support for meeting the metabolic requirements of sick neonates is a tedious time consuming calculation, needs practical expert knowledge and involves the risk of introducing possibly fatal errors. We therefore developed the interactive support system VIE–PNN for calculating the composition of parenteral nutrition solutions (PNS) for neonates at intensive...
متن کاملStudy and Evaluation of Formulation and Nutritional values of parenteral Nutrition Formulae of Iranian Generic Project in Ten Major General Hospitals
Abstract: Parenteral Nutrition Formulae in Iranian Generic Project were studied in 31 patients hospitalized in ten major general hospitals in Tehran and Shiraz. Estimated theoretical energy (Calculated Energy Value or CEE) using Harris- Benedict equations and applying the Cerra stress factor was compared with the amount of energy estimated via indirect calorimetric technique (Measured Energy ...
متن کاملA Newborn with a Congenital Chylothorax
Congenital chylothorax is an uncommon cause of respiratory distress and a life-threatening condition in newborns. It is identified by abnormal accumulation of chyle in the pleural space. Herein, we report a male infant who was born by a successful vaginal delivery. After the first three days of life, he had feeding difficulties and cyanotic episodes during breastfeeding. On admission, physical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Artificial intelligence in medicine
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2002