Validation of a New Test for Schistosoma haematobium Based on Detection of Dra1 DNA Fragments in Urine: Evaluation through Latent Class Analysis
نویسندگان
چکیده
BACKGROUND Diagnosis of urogenital schistosomiasis in chronically infected adults is challenging but important, especially because long term infection of the bladder and urinary tract can have dire consequences. We evaluated three tests for viable infection: detection of parasite specific DNA Dra1 fragments, haematuria and presence of parasite eggs for sensitivity (Se) and specificity (Sp). METHODS Over 400 urine specimens collected from adult volunteers in an endemic area in Western Nigeria were assessed for haematuria then filtered in the field, the filter papers dried and later examined for eggs and DNA. The results were stratified according to sex and age and subjected to Latent Class analysis. CONCLUSIONS Presence of Dra1 in males (Se=100%; Sp=100%) exceeded haematuria (Se=87.6%: Sp=34.7%) and detection of eggs (Se=70.1%; Sp=100%). In females presence of Dra1 was Se=100%: Sp=100%, exceeding haematuria (Se=86.7%: Sp=77.0%) and eggs (Se=70.1%; Sp=100%). Dra1 became undetectable 2 weeks after praziquantel treatment. We conclude detection of Dra1 fragment is a definitive test for the presence of Schistosoma haematobium infection.
منابع مشابه
A Schistosoma haematobium-Specific Real-Time PCR for Diagnosis of Urogenital Schistosomiasis in Serum Samples of International Travelers and Migrants
BACKGROUND Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. METHODOLOGY/PRINCIPAL FINDINGS The PCR was evaluated on ur...
متن کاملDETECTION AND RESTRICTION ANALYSIS OF C YTOMEGALOVIRUS DNA PERSISTING IN HUMAN ATHEROSCLEROTIC PLAQUES USING POLYMERASE CHAIN REACTION
The polymerase chain reaction (PCR) as applied to detection of a foreign DNA in clinical specimens could provide a sensitive instrument for rapid detection of viral DNA persisting in tissues of patients suspected of latent infection. Human cytomegalovirus (HCMV) DNA was found in arterial plaques of patients with atherosclerotic lesions using a PCR assay with nested primer oligonucleotides ...
متن کاملSensitivity and Specificity of a Urine Circulating Anodic Antigen Test for the Diagnosis of Schistosoma haematobium in Low Endemic Settings
BACKGROUND Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings a...
متن کاملGenetic Diversity of Schistosoma haematobium Eggs Isolated from Human Urine in Sudan
The genetic diversity of Schistosoma haematobium remains largely unstudied in comparison to that of Schistosoma mansoni. To characterize the extent of genetic diversity in S. haematobium among its definitive host (humans), we collected S. haematobium eggs from the urine of 73 infected schoolchildren at 5 primary schools in White Nile State, Sudan, and then performed a randomly amplified polymor...
متن کاملDiagnostic Performance of Schistosoma Real-Time PCR in Urine Samples from Kenyan Children Infected with Schistosoma haematobium: Day-to-day Variation and Follow-up after Praziquantel Treatment
BACKGROUND In an effort to enhance accuracy of diagnosis of Schistosoma haematobium, this study explores day-to-day variability and diagnostic performance of real-time PCR for detection and quantification of Schistosoma DNA compared to other diagnostic tools in an endemic area before and after treatment. METHODOLOGY Previously collected urine samples (N = 390) from 114 preselected proven para...
متن کامل