Pedicle Screw Nut Loosening: Potentially Avoidable Causes of Spine Instrumentation Failure

نویسنده

  • Amit Agrawal
چکیده

Copyright C 2014 by Korean Society of Spine Surgery This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Asian Spine Journal • pISSN 1976-1902 eISSN 1976-7846 • www.asianspinejournal.org Received Apr 5, 2013; Revised Apr 7, 2013: Accepted Apr 17, 2013 Corresponding author: Amit Agrawal Department of Neurosurgery, Narayana Medical College Hospital, Chinthareddypalem, Nellore-524003, Andhra Pradesh, India Tel: +91-8096410032, Fax: +91-861-2317962, E-mail: [email protected] Pedicle Screw Nut Loosening: Potentially Avoidable Causes of Spine Instrumentation Failure

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-Endplate Pedicle Pillar System in Unstable Spinal Burst Fractures: Design, Technique, and Mechanical Evaluation

BACKGROUND Short-segment pedicle screw instrumentation (SSPI) is used for unstable burst fractures to correct deformity and stabilize the spine for fusion. However, pedicle screw loosening, pullout, or breakage often occurs due to the large moment applied during spine motion, leading to poor outcomes. The purpose of this study was to test the ability of a newly designed device, the Trans-Endpla...

متن کامل

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

Simultaneous Use of Both Bilateral Intralaminar and Pedicle Screws for C2 Stabilization

Four patients underwent stabilization surgery using both bilateral C2 pedicle screw (PS) and intralaminar screw (LS). Neural and vascular injury resulting from incorrect screw placement was assessed using computed tomography (CT). The evaluation of bone union was assessed by lateral flexion-extension X-ray films and CT. The symptoms were improved in all patients. There were no intraoperative co...

متن کامل

Intraoperative biomechanics of lumbar pedicle screw loosening following successful arthrodesis.

Pedicle screw loosening has been implicated in recurrent back pain after lumbar spinal fusion, but the degree of loosening has not been systematically quantified in patients. Instrumentation removal is an option for patients with successful arthrodesis, but remains controversial. Here, we quantified pedicle screw loosening by measuring screw insertion and/or removal torque at high statistical p...

متن کامل

Pars and pedicle fracture and screw loosening associated with cortical bone trajectory: a case series and proposed mechanism through a cadaveric study.

BACKGROUND CONTEXT Cortical bone trajectory (CBT) technique for pedicle screw placement in the lumbar spine has become more popular since its introduction in 2009. The distinct advantages of using the CBT technique involve increased screw purchase within the cortical bone and reduced surgical dissection. However, contrary to several favorable biomechanical results, there were anecdotal reports ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014