Passive , Nonlinear , Mechanical Structures for Seismic Attenuation

نویسنده

  • Riccardo DeSalvo
چکیده

Gravitational wave detectors aim to detect strain perturbations of space-time on the order of 10−21–10−22 at frequencies between 1 Hz and a few kHz. This space-time strain, integrated over kilometer scale interferometers, will induce movements of suspended mirrors on the order of 10−18–10−19 m. Seismic motion in this frequency band varies between 10−6 m and 10−12 m. Required seismic attenuation factors, as large as 10−12, by far exceed the performance of motion sensors, and are only obtained by means of a chain of passive attenuators. High quality springs in configurations yielding nonlinear response are used to generate attenuation at low frequency. Similarly, nonlinear mechanisms are used in the horizontal direction. A description of some of these systems and some of the technical challenges that they involve is presented. DOI: 10.1115/1.2754305

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system

The 10 m prototype facility at the Albert–Einstein-institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI seismic-attenuation-system (AEI-SAS) uses mechanical anti-springs in order to achieve resonance frequencies below 0.5 Hz. This system provides passive isolation from ground motion by a factor of about 400 in the horizontal d...

متن کامل

Evaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

متن کامل

One hertz seismic attenuation for low frequency gravitational waves interferometers

This article describes a mechanical vertical attenuation system capable to provide large attenuation factors above 1Hz. This system is derived from, and improves, the passive Geometric Anti-Spring seismic attenuation filters minimizing their vertical resonant frequency by means of a tunable electromagnetic spring mounted in parallel with the main spring. The tunable spring is also used to compe...

متن کامل

FRAGILITY CURVES FOR STRUCTURES EQUIPPED WITH OPTIMAL SATMDs

In this paper, a procedure has been presented to develop fragility curves of structures equipped with optimal variable damping or stiffness semi-active tuned mass dampers (SATMDs). To determine proper variable damping or stiffness of semi-active devices in each time step, instantaneous optimal control algorithm with clipped control concept has been used. Optimal SATMDs have been designed based ...

متن کامل

Evaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007