Rotating-hinge knee prostheses are used for reconstruction in cases of severe articular compromise and major bone loss. Biomechanical studies revealed that rotating-hinge designs with long and cylindrical pegs are more stable than devices with short and more tapered ones. Twenty-five patients underwent clinical examination using ultrasound, radiographs, and 3 different rating systems to examine the in vivo stability and functional outcome of 2 rotating-hinge knee systems. Overall, the study revealed that a stable reconstruction could be achieved with both tested devices, with good functional outcome. The results for medial and lateral lift-off during flexion and extension in ultrasonography were comparable, whereas the measured distraction of the Limb Preservation System (LPS/M.B.T.; DePuy, Warsaw, Indiana) was lower compared with the S-ROM Noiles prostheses (DePuy). The implant, the new formed capsule, and the remaining soft tissues have to maintain joint stability. Soft tissue reconstruction, especially the medial gastrocnemius flap, and the newly formed periprosthetic scar seems to prevent distraction of several millimeters. In addition, determining the lift-off with ultrasonography showed that the shape of the peg does not influence implant's stability against lateral directed forces.
منابع مشابه
Total Knee Arthroplasty in Severe Unstable Knee: Case-Report and Literature Review
Multiplanar or global laxity in arthritic knee is rare , most of this patients have neuromuscular disorder (post poliomyelitis , spinal dystrophy) or history of knee trauma. Ligament insufficiency and severe bone loss is significant in this patient. The estimated prevalence for the concurrence of charcot marie-tooth (CMT) with myasthenia gravis (MG) suggests an extremely rare event. We have p...
متن کاملPosterior Dislocation of the Hinge-Post Extension in a Rotating Hinge Total Knee Prosthesis
The rotating hinge knee prosthesis is a popular intervention in patients lacking stability with highly constrained total knee arthroplasty. Despite improvements in design, nonmechanical and mechanical complications continue to be a problem. Dislocation of the hinge has been widely described, mainly due to the component fracture. Few reports describe isolated dislocation of the rotating stem. We...
متن کاملA Comparison of the Postoperative Complications between Two Drainage Methods after Total Knee Arthroplasty
Background: The role of wound drainage after total knee arthroplasty is still considered controversial as althoughclosed drainage systems have been believed to be effective in decreasing the post-operative complications, they couldalso facilitate the bleeding and increase the rate of transfusion and infection. We have conducted the current study tocompare the outcomes superficial subcutaneous, ...
متن کاملRotating-hinge total knee for revision total knee arthroplasty.
Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...
متن کاملManagement of chronic lateral instability due to lateral collateral ligament deficiency after total knee arthroplasty: a case report
INTRODUCTION Lateral instability following total knee arthroplasty (TKA) is a rare condition with limited report of treatment options. The objective of this case presentation is to demonstrate the outcomes of different surgical procedures performed in a single patient with lateral collateral ligament (LCL) deficiency. CASE PRESENTATION We present a case of chronic lateral instability due to L...