Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases
نویسندگان
چکیده
Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.
منابع مشابه
Delayed Cerebrospinal Fluid Leak after Watertight Dural Closure with a Polyethylene Glycol Hydrogel Dural Sealant in Posterior Fossa Surgery: Case Report
A polyethylene glycol (PEG) hydrogel sealant recently has been approved as an adjunct to sutured dural closure in Japan. We treated consecutive six patients with PEG hydrogel sealant in posterior fossa operation. Three of six cases suffered delayed cerebrospinal fluid (CSF) leak after watertight dural closure with the PEG hydrogel sealant, although there was no leak case which was treated with ...
متن کاملA multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.
OBJECTIVE Incisional cerebrospinal fluid (CSF) leakage after cranial surgery is a significant cause of morbidity due to poor wound healing and infection, meningitis, and pseudomeningocele formation. Many common dural closure techniques, such as sutures, autologous grafts, gelatin or collagen sponges, and fibrin glues, are used to achieve watertight closure, although none are US Food and Drug Ad...
متن کاملA Novel Absorbable Hydrogel for Dural Repair: Results of a Pilot Clinical Study
This report details a 47 patient, prospective, non-randomized, single-center clinical study to evaluate the safety and performance of a new synthetic dural sealant as an adjunct to standard surgical dural repair techniques to prevent cerebrospinal fluid (CSF) leakage. A consecutive series of patients scheduled for cranial and spinal intradural surgery each received standard dural closures. Afte...
متن کاملPreliminary investigation of a polyethylene glycol hydrogel "nerve glue"
BACKGROUND Polyethylene glycol (PEG) hydrogel is a biocompatible semi-adherent gel like substance that can potentially augment nerve repair much like a fibrin sealant. Potential advantages of this substance include fast preparation and set up time, as well as adhesion inhibiting properties. The purpose of this study was to perform an initial evaluation of PEG hydrogel in this application. MET...
متن کاملA Cost-benefit Analysis of Using Polyethylene Glycol Hydrogel Sealant versus Fibrin Glue as a Dural Sealant for Posterior Fossa Surgery in the United States
Background: Cerebrospinal fluid (CSF) leaks are a well-known complication of posterior fossa neurosurgery. The use of dural repair adjuncts has been associated with fewer CSF leaks and subsequently, lower medical costs. Objectives: To determine if the use of polyethylene glycol hydrogel sealant (DuraSeal dural sealant system [DuraSeal]), resulted in cost savings in the United States compared to...
متن کامل