Central venous cannulation is associated with a number of serious complications like arterial punction and pneumothorax and with discomfort for the awake patient when repeated attempts are made. Ultrasound guidance during cannulation has been shown to reduce complications, increase the success rate and thus reduce the need for multiple catheter placement attempts. We describe two methods using ultrasound for central venous cannulation and we recommend the use of ultrasound guidance, particularly in high-risk patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature.

OBJECTIVE To evaluate the effect of real-time ultrasound guidance using a regular or Doppler ultrasound technique for placement of central venous catheters. DATA SOURCES We searched for published and unpublished research using MEDLINE, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants. STUDY SELECTION From a poo...

متن کامل

Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

BACKGROUND Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid an...

متن کامل

9 Ultrasound Guided Vascular Access

Vascular access is an important procedure for clinicians to master. Chronic medical conditions, intravenous drug use, and obesity can all make placements of vascular catheters in central and peripheral veins challenging and time-consuming. External landmarks have traditionally guided the placement of the needle for the performance of central venous catheterization. The proximity of such structu...

متن کامل

Should ultrasound guidance be used for central venous catheterisation in the emergency department?

In September 2002, the National Institute of Clinical Excellence (NICE) issued guidelines for England and Wales suggesting that ultrasound guidance should be used for all electives, and should be considered for most emergency, central venous catheterisations.1 These guidelines propose a major change of practice for most clinicians practising in UK Emergency Departments. There are also resource ...

متن کامل

Ultrasound detection of guidewire position during central venous catheterization.

INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke

دوره 119 24  شماره 

صفحات  -

تاریخ انتشار 1999