Score Evaluation of MRI Sequence Type Related Artifacts after Interbody Fusion with Metallic Implants—A Spine Specimen Study

نویسندگان

  • Thorsten Ernstberger
  • Gottfried Buchhorn
  • Gabert Heidrich
چکیده

Introduction: According to anterior spine fusion intervertebral disc spacers made of titanium or cobalt-chromium alloys are of special interest. With regard to postoperative problems implant related artifacts can lead to a decreased MRI evaluation. The focus of this study was to compare the respective implant artifact range dependend on different MRI sequences. To simplify artifact evaluation we introduced in this study a new developed 0-1-2 score. Material and Methods: We performed an MRI artifact evaluation of 2 different metallic intervertebral disc spacers (cobalt-chromiumand titanium alloy). A carcass porcine spine was employed. Considering 12 defined spinal regions of interest we evaluated the respective implant artifact properties independent from the total artifact volume by using a new developed 0-1-2 score. The artifact range was documented for 15 different MRI-sequences. Results: For the titanium spacer as well as the cobalt-chromium-spacer an MRI evaluation of the implant/disc space situation could not be carried out. In contrast to the cobalt chromium spacer the titanium spacer allowed a good differentiation of the spinal canal opposite to the implant. Optimal MRI imaging results for both metallic intervertebral disc spacers could be achieved considering TSE sequences. Conclusion: A comparison of these two metallic spacers showed in all examined sequences clear advantages in favour of the titanium spacer. The best MRI representation of both tested implants by reducing implant related artifacts could be achieved with fast spin echo (TSE) sequences. In spite of the use of TSE sequences a variability of susceptibility artifacts has to be included with regard to implant shape and material. With regard to the results of this study the easy use of a new developed artifact score represented a useful help to compare implant related MRI artifact properties independent from the actual implant related total artifact volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant-related MRI artifacts of determined interbody test spacers: artifact calculations due to implant parameters in a porcine spine model

Aim: Intervertebral spacers for anterior spine fusion are made of different materials, which can affect the post-fusion MRI scans. Susceptibility artifacts specially for implants made of titanium alloys can decrease the image quality. This study focused on the influence of determined implant parameters like shape and implant volume in MRI artifacting independent from selected MRI-sequences. Met...

متن کامل

Three Dimensional Artifact Free Visualization of Different Metallic Intervertebral Disc Spacers With Flat Panel Detector Volume CT (FD-VCT): A Comparative Cadaveric Spine Study

Image quality and implant detectability by conventional imaging methods are suboptimal for perioperative spinal diagnostics, primarily limited by implant-related artifacts. This preclinical experimental study aimed to evaluate the imaging quality of two different metallic intervertebral spacers used as stand alone cages examined by flatpanel detector-based volumetric computed tomography (FD-VCT...

متن کامل

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

Imaging pitfalls of interbody spinal implants.

STUDY DESIGN A variety of interbody implants were imaged by computed tomography and plain radiography within cadaveric spines to evaluate their basic imaging characteristics. OBJECTIVES Sources of interpretation error by both computed tomography and plain radiography of interbody implants were investigated. SUMMARY OF BACKGROUND DATA Lucencies have been reported around bone dowel implants i...

متن کامل

PEEK Versus Ti Interbody Fusion Devices: Resultant Fusion, Bone Apposition, Initial and 26-Week Biomechanics.

STUDY DESIGN Comparative evaluation of in vitro and in vivo biomechanics, resulting fusion and histomorphometric aspects of polyetheretherketone (PEEK) versus titanium (Ti) interbody fusion devices in an animal model with similar volumes of bone graft. OBJECTIVE Identify differences in the characteristics of fusion and biomechanics immediately following implantation (time 0) and at 26 weeks w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013