Shuttle walking test: a new approach for evaluating patients with pacemakers.

نویسندگان

  • G E Payne
  • J D Skehan
چکیده

OBJECTIVE To validate an incremental field walking test, the shuttle walking test, as a means of assessing pacing modes and to aid programming of rate responsive pacemakers. DESIGN Three separate groups of patients were recruited. Reproducibility (n = 10) of the shuttle walking test was assessed by performing three consecutive tests. Comparison of the shuttle walking test with a 10 min walk was assessed in 20 patients. In the third group (n = 10) patients with rate responsive pacemakers were programmed to either VVI fixed rate 70 beats/min or VVIR with the optimal rate response to show the discriminative value of the test. SETTING Pacing clinic in a regional cardiothoracic centre. PATIENTS 30 patients with chronotropic competence and dual chamber pacemakers with varying functional capacity and 10 patients with rate responsive pacemakers. INTERVENTIONS Continuous haemodynamic monitoring was obtained using an ambulatory nuclear monitor, the Capintec VEST. Two exercise tests either shuttle walking test or 10 min corridor walk. The shuttle walk is an incremental walking test conducted on a 10 m course where the walking speed is dictated by bleeps on an audio cassette. RESULTS Reproducibility was demonstrated over three consecutive tests with mean (1 SD) exercise times of 7.6 (1.7) min, 7.7 (1.6), and 7.7 (1.7) min. During the shuttle walk the test patients walked for a mean of 8.3 (1.2) min producing peak relative cardiac outputs of 78 (21) end diastolic volume/min compared with 64.9 (17) end diastolic volume/min for the 10 min walk (P < 0.001); peak heart rates were 118 and 104 beats/min (P < 0.03) respectively. In the third group relative peak cardiac output was significantly greater in VVIR (70 (24) v VVI 52 (15) end diastolic volume/min) (P < 0.009) as were exercise times (VVIR 8.8 (1.3) min v VVI 8.1 (1.3) min) (P < 0.003). CONCLUSIONS The shuttle walk is an easy test to administer, requiring little equipment. It produces a symptom limited maximal performance and will be a useful aid to pacemaker programming as it is reproducible and able to show differences in exercise capacity between pacing modes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a shuttle walking test of disability in patients with chronic airways obstruction.

BACKGROUND The aim was to develop a standardised and externally paced field walking test, incorporating an incremental and progressive structure, to assess functional capacity in patients with chronic airways obstruction. METHODS The usefulness of two different shuttle walking test protocols was examined in two separate groups of patients. The initial 10 level protocol (group A, n = 10) and a...

متن کامل

Comparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitation.

The purpose of this study was to investigate the relationship between performance on the shuttle walking test and maximal oxygen uptake (VO2max) during a conventional treadmill test in patients with chronic airflow limitation. Two different techniques were used to measure oxygen consumption, i.e. conventional Douglas bag techniques (treadmill test) and a portable oxygen consumption meter (shutt...

متن کامل

The shuttle walking test: a reproducible method for evaluating the impact of shortness of breath on functional capacity in patients with advanced cancer.

BACKGROUND Breathlessness leading to exercise limitation is common in patients with advanced cancer and is ineffectively treated. There are few research data to guide clinicians on best practice. The shuttle walking test has been validated for some conditions such as chronic obstructive pulmonary disease but not for advanced cancer. One of the well documented difficulties of doing clinical rese...

متن کامل

Pilot investigation of the oxygen demands and metabolic cost of incremental shuttle walking and treadmill walking in patients with cardiovascular disease

OBJECTIVE To determine if the metabolic cost of the incremental shuttle-walking test protocol is the same as treadmill walking or predicted values of walking-speed equations. SETTING Primary care (community-based cardiac rehabilitation). PARTICIPANTS Eight Caucasian cardiac rehabilitation patients (7 males) with a mean age of 67±5.2 years. PRIMARY AND SECONDARY OUTCOME MEASURES Oxygen con...

متن کامل

CHRONIC OBSTRUCTIVE PULMONARY DISEASE Six-minute walking versus shuttle walking: responsiveness to bronchodilation in chronic obstructive pulmonary disease

Background: The responsiveness of the endurance shuttle walk to functional changes following bronchodilation has recently been reported. The current literature suggests that the 6 min walking test (6MWT) is less responsive to bronchodilation than the endurance shuttle walk. Aim: To compare bronchodilator-induced changes in exercise performance with the 6MWT and the endurance shuttle walk. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 75 4  شماره 

صفحات  -

تاریخ انتشار 1996