Deformation and fracture incidence of Reciproc instruments: a clinical evaluation.

نویسندگان

  • G Plotino
  • N M Grande
  • P F Porciani
چکیده

AIM To investigate the incidence of fracture and deformation observed on Reciproc instruments after clinical use. METHODOLOGY A total of 1696 Reciproc NiTi instruments that were discarded after normal clinical usage over 30 months were collected. Of these 1580 instruments were R25 (93%), 76 were R40 (5%), and 40 were R50 (2%). The treatments included 3780 root canal preparations, 3023 primary treatments and 757 retreatments. Root canal preparation was standardized and followed the manufacturer's directions for the use of Reciproc files without creating prior glide path with hand instruments. In retreatment cases, Reciproc R25 instrument was used to remove all filling material and to complete the preparation. Each instrument was used for shaping only one tooth. All the instruments used were inspected under a microscope to detect signs of fracture or deformation and, if any fracture existed, the length of the files was measured. Data were analysed using a chi-square test with a level of significance set at P < .05. RESULTS A total of 8 Reciproc R25 instruments fractured during treatment, which represents 0.47% of the number of instruments used and 0.21% of the root canals treated. Five instruments fractured in primary treatment cases and three instruments during retreatments. Six Reciproc R25 deformed during clinical use (0.35% of the number of instruments used and 0.15% of the root canals treated), four during retreatments and two during primary treatments. The deformation reported was unwinding of the blades, one at 1 mm from the tip and five between 2 and 3 mm from the tip. No deformations or fracture were registered for the Reciproc R40 and R50 instruments. CONCLUSIONS Root canal instrumentation following the manufacturer's instructions can be performed with Reciproc instruments with a very low incidence of instrument fracture and deformation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals

Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...

متن کامل

Cyclic fatigue of Reciproc and WaveOne reciprocating instruments.

AIM To evaluate the cyclic fatigue resistance of Reciproc(®) and WaveOne(®) instruments in simulated root canals. METHODOLOGY Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc(®) R25 and group B: WaveOne(®) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instrument's ...

متن کامل

Mechanical characteristics of counterfeit Reciproc instruments: a call for attention.

AIM To report the main differences seen by direct visual inspection between original and counterfeit Reciproc instruments, together with an evaluation of instrument bending resistance, cyclic fatigue, surface finish, Vickers microhardness and chemical composition. METHODOLOGY The visual aspects of original Reciproc R25 (VDW, Munich, Germany) and counterfeit Reciproc R25 instruments (claimed t...

متن کامل

A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 ...

متن کامل

Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use

OBJECTIVES The aim of the present study was to investigate the incidence of deformation and fracture of twisted file adaptive nickel-titanium instruments after repeated clinical use and to identify and check whether the three instruments within the small/medium sequence showed similar or different visible signs of metal fatigue. MATERIAL AND METHODS One-hundred twenty twisted file adaptive (T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2015