Krypton-enhanced ventilation CT with dual energy technique: experimental study for optimal krypton concentration.

نویسندگان

  • Yong Eun Chung
  • Sae Rom Hong
  • Mi-Jung Lee
  • Myungsu Lee
  • Hye-Jeong Lee
چکیده

PURPOSE/AIM OF THE STUDY To assess the feasibility of krypton-enhanced ventilation CT using dual energy (DE) technique for various krypton concentrations and to determine the appropriate krypton concentration for DE ventilation CT through an animal study. MATERIALS AND METHODS Baseline DECT was first performed on seven New Zealand white rabbits. The animals were then ventilated using 20%, 30%, 40%, 50%, 60%, to 70% krypton concentration, and DECT was performed for each concentration. Krypton extraction was performed through a workstation, and results were displayed on a color map. Overlay Hounsfield unit (HU) values were obtained by two observers in consensus readings. A linear mixed model was used to correlate overlay HU values and krypton concentrations. Visual assessments of the homogeneity of krypton maps were also performed. RESULTS Mean overlay HU values according to krypton concentration were as follows; 20% krypton, 1.68 ± 5.15; 30% krypton, 3.73 ± 5.93; 40% krypton, 6.92 ± 5.51; 50% krypton, 10.88 ± 5.17; 60% krypton, 14.54 ± 4.23; and 70% krypton, 18.79 ± 3.63. We observed a significant correlation between overlay HU values on krypton maps and krypton concentrations (P < .001). For the krypton color maps, all observers determined universal enhancement on the 70% krypton map for all animals. CONCLUSION It is feasible to evaluate lung ventilation function using DECT with a krypton concentration of at least 70%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of krypton atoms on the structure of hydrogenated amorphous carbon deposited by plasma enhanced chemical vapor deposition

Hydrogenated amorphous carbon a-C:H films were prepared by plasma enhanced chemical vapor deposition using methane CH4 plus krypton Kr mixed atmosphere. The depositions were performed as function of the bias voltage and krypton partial pressure. The goal of this work was to study the influence of krypton gas on the physical properties of a-C:H films deposited on the cathode electrode. Krypton c...

متن کامل

Krypton Tagging Velocimetry for Use in High-Speed Ground-Test Facilities

In this work, we present the excitation strategy, experimental setup, and results of an implementation of krypton tagging velocimetry (KTV) as applied to an underexpanded jet of three mixtures. We demonstrate that the KTV technique can be employed with gas mixtures of relatively low krypton concentration (0.5% Kr/99.5% N2) and conclude that the KTV technique shows promise as a velocimetry diagn...

متن کامل

Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements.

Xenon computed tomography (Xe-CT) is used to estimate regional ventilation by measuring regional attenuation changes over multiple breaths while rebreathing a constant Xe concentration ([Xe]). Xe-CT has potential human applications, although anesthetic properties limit [Xe] to <or=35%. We investigate effects of lower [Xe], including a low [Xe]-krypton (Kr) combination, on time constant (TC) det...

متن کامل

An Ab Initio Study of the Mono- and Difluorides of Krypton

An ab initio study of the mono-and difluorides of krypton. Results from ab initio calculations at the CCSD͑T͒ level of theory are presented for krypton monofluoride ͑KrF͒, krypton monofluoride cation (KrF ϩ), linear, ground-state krypton difluoride (KrF 2), the triplet state of krypton difluoride, and the krypton–fluorine van der Waals complex (Kr–F 2). These are the first calculations demonstratin...

متن کامل

Theoretical Treatment of Krypton Ion Beam Bombardement in Zinc Target

The manuscript reports a study of Kr ion implantation in a Zn target in the 10-50 keV energy range at different source parameters, which combines experimental data and simulation with the SRIM package. The implanted thickness for the 45 keV was found to be 10 μm. The ion penetration depths for different films at different energies (10-50 keV) were calculated using SRIM computer program and foun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental lung research

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2014