Modified micro-scale enzymatic method for plasma ammonia in newborn and pediatric patients; comparison with a modified cation-exchange procedure.
نویسندگان
چکیده
We modified two "kit" procedures for plasma ammonia to make them suitable for use with newborn and pediatric patients. Available methods either require too large a specimen, are insufficiently sensitive in the normal range, or are too cumbersome. One was an enzymatic (Sigma Chemical Co., St. Louis, Mo. 63178), the other a cation-exchange (Hyland, Costa Mesa, Calif. 92626) method. The modified micro-scale enzymatic method requires 100 microliter of plasma (CV at 38 micronmol/liter, 8%). Reagent costs per patient assay, including controls and standards, are currently $0.53. An assay run can be completed in 30 min. The modified cation-exchange method requires 200 microliter of plasma; the within-run CV is 12% for a concentration of 34.2 micronmol/liter. Reagents currently cost $0.74 per assay and each run requires less than 2 h to complete. The correlation coefficient for the two methods was 0.98.
منابع مشابه
Comparison Between Fone’s Method and Modified Bass Method of Toothbrushing for Children with Down Syndrome in West Java, Indonesia
Background and Aim: Down syndrome (DS) is a delayed physical and mental development caused by an abnormality in chromosome 21, resulting in the presence of three chromosomes (trisomy 21). Several methods of toothbrushing, such as the Scrub, Bass, Charters, Fone’s, Roll, and Stillman’s methods have been introduced. The aim of this study was to evaluate oral hygiene levels after toothbrushing wit...
متن کاملN-octyl-modified magnetite NPs for optimization of solid phase extraction for trace analysis of phenytoin in real samples
objective: Phenytoin is an anti-seizure medication used to treat epilepsy, as well as to control arrhythmias (irregular heartbeat) and to treat migraine headaches and nerve pain. It is recommended to determine the amount of this drug in the blood to control the seizure and prevent its toxicity. In the present study, a sensitive and simple procedure based on the dispersive solid phase extraction...
متن کاملFree Vibration Analysis of Size-Dependent, Functionally Graded, Rectangular Nano/Micro-plates based on Modified Nonlinear Couple Stress Shear Deformation Plate Theories
In the present study, a vibration analysis of functionally graded rectangular nano-/microplates was considered based on modified nonlinear coupled stress exponential and trigonometric shear deformation plate theories. Modified coupled stress theory is a non-classical continuum mechanics theory. In this theory, a material-length scale parameter is applied to account for the effect of nanostructu...
متن کاملValidity of Modified Ashworth Scale as a Measure of Wrist Spasticity in Stroke Patients
Objectives: There are some controversies about the value of modified Ashworth Scale (MAS) for assessing spasticity. The goal of this study was to investigate if there is any correlation between scores obtained from MAS for wrist spasticity and electrophysiological recordings as the objective measure of spasticity. Methods: In this cross-sectional study, 34 stroke patients were employed. Wris...
متن کاملLength Scale Effect on Vibration Analysis of Functionally Graded Kirchhoff and Mindlin Micro-Plates
In this paper, the modified couple stress theory is used to study vibration analysis of functionally graded rectangular micro-plates. Considering classical and first order plate theories, the couple governing equations of motion are obtained by using the Hamilton’s principle. Considering an assumed mode method, the accurate size dependent natural frequencies are established for simply supported...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 12 شماره
صفحات -
تاریخ انتشار 1978