Comparative analysis of the bronchodilator response measured by impulse oscillometry (IOS), spirometry and body plethysmography in asthmatic children.

نویسندگان

  • J M Olaguíbel
  • M J Alvarez-Puebla
  • M Anda
  • B Gómez
  • B E García
  • A I Tabar
  • E Arroabarren
چکیده

BACKGROUND Asthma is common among young children. The assessment of respiratory resistance by the impulse oscillometry system (IOS), based on the superimposition of respiratory flow by short-time impulses, requires no patient active collaboration. AIM We evaluated the baseline repeatability and bronchodilator response of IOS indices in preschool children, their correlation with spirometry and whole body plethysmography, and differences between atopic and nonatopic children. PATIENTS AND METHODS Thirty-three asthmatic children (3-6 yrs.) underwent IOS measurement (R5rs, R20rs and X5rs) by triplicate at the baseline, after placebo and after salbutamol inhalation. Spirometry (FEV1) and whole body plethysmography (sRaw) were made at the baseline and after salbutamol. Baseline within-test (coefficient of variation: CV%) and between-test repeatability (baseline-placebo) were addressed. Bronchodilator response was evaluated by the SD index (change in multiples of the between-test repeatability). RESULTS Baseline repeatability for R5rs was 4.1%. Its values decreased by 2SD after salbutamol inhalation, and correlated with FEV1 and sRaw at both, baseline (r=-0.51 and r=0.49) and post-salbutamol (r=-0.63 and r=0.54). A trend towards correlation between salbutamol-induced changes in R5rs and in sRaw (r=0.33) was observed. Atopic and non-atopic children showed no differences in lung function. CONCLUSION IOS was well accepted by young asthmatic children and provided reproducible and sensitive indices of lung function. Resistance values obtained by IOS at low frequency (R5rs) were reproducible and correlated with spirometry and plethysmographic values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bronchodilator Response Assessment of the Small Airways Obstructive Pattern

BACKGROUND A concomitant decrease in FEV1 and FVC with normal FEV1/FVC ratio and TLC defines small airways obstructive pattern (SAOP) and constitutes a classic pitfall of pulmonary-function-tests interpretation. OBJECTIVE To evaluate the prevalence of flow- (FEV1 increase≥12% and 200 mL), volume- (FVC or inspiratory capacity [IC] increase≥12% and 200 mL), flow and volume-, and non-response to...

متن کامل

Retrospective Observations on the Ability to Diagnose and Manage Patients with Asthma through the Use of Impulse Oscillometry: Comparison with Spirometry and Overview of the Literature

OBJECTIVE Impulse oscillometry (IOS) is an evolving technology for the diagnosis and followup of patients with asthma. Our objective is to review the findings on patients who underwent both spirometry and IOS during clinical evaluations of their asthma. The goal was to retrospectively evaluate IOS during the initial diagnosis and followup of patients with asthma in comparison with spirometry. ...

متن کامل

Airway Dysfunction in Obesity: Response to Voluntary Restoration of End Expiratory Lung Volume

INTRODUCTION Abnormality in distal lung function may occur in obesity due to reduction in resting lung volume; however, airway inflammation, vascular congestion and/or concomitant intrinsic airway disease may also be present. The goal of this study is to 1) describe the phenotype of lung function in obese subjects utilizing spirometry, plethysmography and oscillometry; and 2) evaluate residual ...

متن کامل

Advantage of impulse oscillometry over spirometry to diagnose chronic obstructive pulmonary disease and monitor pulmonary responses to bronchodilators: An observational study

OBJECTIVES This retrospective study was a comparative analysis of sensitivity of impulse oscillometry and spirometry techniques for use in a mixed chronic obstructive pulmonary disease group for assessing disease severity and inhalation therapy. METHODS A total of 30 patients with mild-to-moderate chronic obstructive pulmonary disease were monitored by impulse oscillometry, followed by spirom...

متن کامل

Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance

Classification of COPD into different GOLD stages is based on forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) but has shown to be of limited value. The aim of the study was to relate spirometry values to more advanced measures of lung function in COPD patients compared to healthy smokers. The lung function of 65 COPD patients and 34 healthy smokers was investigated using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of investigational allergology & clinical immunology

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2005