Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimators.

نویسندگان

  • M Langer
  • V Thai
  • L Papiez
چکیده

Leaf sequencing algorithms may use an unnecessary number of monitor units or segments to generate intensity maps for delivery of intensity modulated radiotherapy (IMRT) using multiple static fields. An integer algorithm was devised to generate a sequence with the fewest possible segments when the minimum number of monitor units are used. Special hardware related restrictions on leaf motion can be incorporated. The algorithm was tested using a benchmark map from the literature and clinical examples. Results were compared to sequences given by the routine of Bortfeld that minimizes monitor units by treating each row independently, and the areal or reducing routines that use fewer segments at the price of more monitor units. The Bortfeld algorithm used on average 58% more segments than provided by the integer algorithm with bidirectional motion and 32% more segments than did an integer algorithm admitting only unidirectional sequences. The areal algorithm used 48% more monitor units and the reducing algorithm used 23% more monitor units than did the bidirectional integer algorithm, while the areal and reducing algorithms used 23% more segments than did the integer algorithm. Improved leaf sequencing algorithms can allow more efficient delivery of static field IMRT. The integer algorithm demonstrates the efficiencies possible with an improved routine and opens a new avenue for development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Sequencing of Dynamic Multileaf Collimators

Dynamic multileaf collimator (DMLC)-intensity modulated radiation therapy (IMRT) is used to delivery intensity-modulated beams using an MLC, with the leaves in motion. DMLC-IMRT requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC while the beam is on. It is imperative that the fluence map delivered using the leaf sequence file be as...

متن کامل

Minimizing delivery time and monitor units in static IMRT by leaf-sequencing.

Intensity-modulated radiation therapy (IMRT) requires the determination of the appropriate multileaf collimator settings to deliver an intensity map. The purpose of this work was to attempt to reduce the number of segments required for IMRT delivery and the number of monitor units required to deliver an intensity map. An intensity map may be written as a matrix. Leaf sequencing was formulated a...

متن کامل

Reducing the number of monitor units in multileaf collimator field segmentation.

Multileaf collimators (MLCs) are the prevailing tool for the realization of radiation fields in intensity modulated radiation therapy (IMRT). One step in the treatment planning is to determine a set of leaf positions realizing a certain intensity modulated radiation field. In this paper we suggest two extensions in the use of the MLC that lead to considerable savings in terms of monitor units, ...

متن کامل

Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery.

Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment ...

متن کامل

A new mathematical model for intensity matrix decomposition using multileaf collimator

Cancer is one of the major causes of death all over the globe and radiotherapy is considered one of its most effective treatment methods. Designing a radiotherapy treatment plan was done entirely manually in the past. RecentlyIntensity Modulated Radiation Therapy (IMRT) was introduced as a new technology with advanced medical equipmentin the recent years. IMRT provides the opportunity to delive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 12  شماره 

صفحات  -

تاریخ انتشار 2001