Biomechanical and morphological differences between the sclera canal ring and a peripheral sclera ring in the porcine eye.

نویسندگان

  • Naim Terai
  • Ursula Schlötzer-Schrehardt
  • Eberhard Spoerl
  • Karin Hornykewycz
  • Janek Haentzschel
  • Michael Haustein
  • Lutz E Pillunat
چکیده

AIM To investigate a possible association between the biomechanical load and unload behaviour and the elastin content of the sclera canal ring (SCR) and a superiorly localized sclera ring (SPS) in the porcine eye. METHODS Two sclera rings were trephined from each of 40 porcine eyes, one containing the SCR and the other an SPS. The load and the unload curves were measured in the extension range of 0-2.0 mm by a biomaterial tester. Hysteresis was determined from the area enclosed by the loading and unloading curve. Histochemical staining with resorcin-fuchsin and morphometric analysis of paraffin-embedded sections of both rings were performed to detect the area occupied by elastin fibres. RESULTS At 1 mm extension, the mean load of the SCR was 0.89 ± 0.22 N and that of the SPS 1.13 ± 0.19 N, which was not significantly different between both rings (p > 0.05). Mean hysteresis in the SCR was 1.55 ± 0.30 N × mm and 1.90 ± 0.18 N × mm in the SPS, which was significantly different between both rings (p = 0.01). Mean sclera thickness was 986 μm in the SCR (range: 900-1,060 μm) and 971 μm in the SPS (range: 800-1,200 μm) without a statistically significant difference between both sclera rings (p = 0.78). The area occupied by elastin fibres was 15.5 ± 3.4% in the SCR and 4.5 ± 1.5% in the SPS, which was significantly different between both rings (p = 0.0001). CONCLUSION Hysteresis in the SCR was significantly lower than in the SPS, indicating a higher elasticity of the SCR in the porcine eye. This effect could be explained by a higher content of elastin in the surrounding ring of the peripapillary optic nerve head providing reversible contraction in cases of intra-ocular pressure variations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Riboflavin/Ultraviolet-A Cross-Linking in Porcine, Rabbit, and Human Sclera

PURPOSE To compare the biomechanical properties of porcine, rabbit, and human sclera before and after riboflavin/ultraviolet-A (UVA) collagen cross-linking (CXL). METHODS Eight rabbits, 8 porcine eyeballs, and 8 human eyeballs were included. One rabbit eye and half of each bisected human and porcine eyeball were treated with riboflavin/UVA CXL. Untreated fellow rabbit eyes and eyeball halves ...

متن کامل

Residual deformations in ocular tissues.

Residual deformations strongly influence the local biomechanical environment in a number of connective tissues. The sclera is known to be biomechanically important in healthy and diseased eyes, such as in glaucoma. Here, we study the residual deformations of the sclera, as well as the adjacent choroid and retina. Using freshly harvested porcine eyes, we developed two approaches of quantifying r...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

Experimental surface strain mapping of porcine peripapillary sclera due to elevations of intraocular pressure.

To experimentally characterize 2D surface mapping of the deformation pattern of porcine peripapillary sclera following acute elevations of intraocular pressure (IOP) from 5 mm Hg to 45 mm Hg. Four porcine eyes were obtained within 48 h postmortem and dissected to the sclera. After the anterior chamber was removed, each posterior scleral shell was individually mounted at the equator on a custom-...

متن کامل

Material properties of the posterior human sclera.

To characterize the material properties of posterior and peripapillary sclera from human donors, and to investigate the macro- and micro-scale strains as potential control mechanisms governing mechanical homeostasis. Posterior scleral shells from 9 human donors aged 57-90 years were subjected to IOP elevations from 5 to 45mmHg and the resulting full-field displacements were recorded using laser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic research

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2012