POHANG NEUTRON FACILITY BASED ON 100-MeV ELECTRON LINAC

نویسندگان

  • G. N. Kim
  • Y. S. Lee
  • H. S. Kang
  • M. H. Cho
  • I. S. Ko
  • W. Namkung
چکیده

Pohang Neutron Facility (PNF) is a pulsed neutron facility based on the 100-MeV electron linear accelerator. It was constructed for nuclear data production in Korea, and it consists of an electron linear accelerator, a watercooled Ta target with a water moderator and a time-offlight path with an 11 m length. The 100-MeV electron linac uses a thermionic RF-gun, an alpha magnet, four quadrupole magnets, two SLAC-type accelerating sections, a quadrupole triplet, and a beam-analyzing magnet. In design of a water-cooled Ta target, we used the Monte Carlo simulation codes, EGS4 and MCNP version 4B. The neutron energy spectrum is measured for different water levels inside the moderator and compared with the calculation results by the Monte Carlo N-Particle (MCNP) transport code system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoneutron Spectrum at Pohang Neutron Facility Based on 100-mev Electron Linac

Pohang Neutron Facility (PNF) is a pulsed neutron facility based on the 100-MeV electron linear accelerator. It was constructed for nuclear data production in Korea, and it consists of an electron linear accelerator, a watercooled Ta target with a water moderator and a time-offlight path with an 11 m length. The 100-MeV electron linac uses a thermionic RF-gun, an alpha magnet, four quadrupole m...

متن کامل

Pulsed Neutron Source Using 100-mev Electron Linac at Pohang Accelerator Laboratory

The Pohang Accelerator Laboratory operates an electron linac for a pulsed neutron source as one of the long-term nuclear R&D programs at the Korea Atomic Energy Research Institute. The designed beam parameters are as follows; The nominal beam energy is 100 MeV, the maximum beam power is 10 kW, and the beam current is varied from 300 mA to 5A depends on the pulse repetition rate. The linac has t...

متن کامل

Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac

Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Optimum shielding structure for the wall of medical LINAC facility

When considering the space limit of high energy LINAC facility in a hospital, the design of shielding wall is strongly required to optimize the wall thickness. Shielding wall usually consists of concrete, and iron plate is sometimes added in concrete to decrease the wall thickness. We investigated the optimum design of the shielding wall in medical LINAC facility by simulation. The calculations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001