Fixation stability measurement using the MP1 microperimeter.

نویسندگان

  • Michael D Crossland
  • Hannah M P Dunbar
  • Gary S Rubin
چکیده

PURPOSE The Nidek microperimeter (MP1, Nidek Instruments, Italy) is a microperimetry device that also assesses fixation stability. The MP1 does not use the method of quantifying fixation stability by calculating a bivariate contour ellipse area (BCEA). Here we compare the MP1 fixation quantification with the BCEA technique by correlating these values to various parameters of reading known to be related to fixation stability. METHODS Twenty-five people with age-related macular disease were assessed. Eye position was recorded using the MP1 during a fixation task. Fixation score and central 2 degrees and central 4 degrees values were obtained from the MP1. Bivariate contour ellipse area values were calculated from raw fixation data. Reading was assessed using MNREAD, Rapid Serial Visual Presentation, and European reading tests. RESULTS Fixation data could not be collected for two observers. For the other 23 participants, the MP1 fixation scores were very poorly related to reading parameters. In contrast, there was a significant relationship between fixation stability assessed using the BCEA technique and Rapid Serial Visual Presentation reading speed (r = -0.59, P < 0.01), European reading test reading error rate (r = 0.66, P < 0.01), and MNREAD peak reading speed (r = 0.55, P < 0.05). CONCLUSION Using the software supplied with the MP1 does not adequately quantify fixation stability in people with age-related macular disease. We recommend that the BCEA technique is used to quantify fixation stability when using the MP1 microperimeter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vitrectomy and Microperimetry of an Accidental Macular Hole Caused by Nd:YAG Laser

A 31-year-old man sustained a 1,064-nm Q-switched Nd:YAG laser injury to his left eye. One month after the injury, the fundus and optical coherence tomography (OCT) examination demonstrated a full-thickness macular hole of approximately 820 μm in diameter. After vitrectomy and internal limiting membrane peeling, OCT showed closure of the hole and a marked thinning of the foveal depression. Afte...

متن کامل

Reference Clinical Database for Fixation Stability Metrics in Normal Subjects Measured with the MAIA Microperimeter

PURPOSE The purpose of this study was to establish a normal reference database for fixation stability measured with the bivariate contour ellipse area (BCEA) in the Macular Integrity Assessment (MAIA) microperimeter. METHODS Subjects were 358 healthy volunteers who had the MAIA examination. Fixation stability was assessed using two BCEA fixation indices (63% and 95% proportional values) and t...

متن کامل

Microperimetry--comparison between the micro perimeter 1 and scanning laser ophthalmoscope--fundus perimetry.

PURPOSE To compare microperimetry using the scanning laser ophthalmoscope (SLO, Rodenstock, Germany) and the recently introduced Micro Perimeter 1 (Nidek Technologies, Italy). DESIGN Prospective comparative observational study. METHODS Fundus perimetry with static threshold perimetry was performed using the SLO and the MP1 in 68 eyes of 40 consecutive patients with different retinal disease...

متن کامل

Retinal specific measurement of dark-adapted visual function: A validation study

Background: Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fix...

متن کامل

Retinal specific measurement of dark-adapted visual function: validation of a modified microperimeter

BACKGROUND Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fixa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Retina

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2009