Do Automated Peritoneal Dialysis and Continuous Ambulatory Peritoneal Dialysis Have the Same Clinical Outcomes? A Ten-year Cohort Study in Taiwan
نویسندگان
چکیده
This paper reports a comprehensive comparison for mortality and technique failure rates between automated peritoneal dialysis (APD) and continuous ambulatory peritoneal dialysis (CAPD) in Taiwan. A propensity-score matched cohort study was conducted by retrieving APD and CAPD patients identified from the Taiwan National Health Insurance Research Database between 2001 and 2010. The main outcomes were the 5-year mortality and technique failure rates. Further analyses were then carried out based upon the first (2001-2004), second (2005-2007), and third (2008-2010) sub-periods. Similar baseline characteristics were identified for APD (n = 2,287) and CAPD (n = 2,287) patients. The proportion on APD therapy increased rapidly in the second sub-period. As compared to CAPD patients of this sub-period, APD patients had a significantly higher risk of mortality (HR, 1.37; 95% CI 1.09-1.72; p < 0.01) and technique failure (HR, 1.43; 95% CI, 1.10-1.86; p < 0.01), particularly in the first year after peritoneal dialysis commencement. However, APD patients had similar mortality and technique failure rates to those of CAPD patients throughout the full sample period and the first and third sub-periods. These findings do not suggest the presence of a clear advantage of CAPD over APD. Differences observed between these two modalities might be attributed to specials circumstances of sub-periods.
منابع مشابه
ارایه مدلی جهت پیشبینی بقای بیماران دیالیز صفاقی با استفاده از الگوریتمهای دادهکاوی
Background: Peritoneal dialysis is one of the most commonly used treatment methods for the patients with end stage renal failure. In recent years, the mortality rate of patients under this treatment has decreased; however, long-term survival is still an important challenge for health systems. The present study aimed to predict the survival of continuous ambulatory peritoneal dialysis patients. ...
متن کاملCorrelation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift
Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...
متن کاملEffectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study
Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...
متن کاملAutomated Peritoneal Dialysis Is Associated with Better Survival Rates Compared to Continuous Ambulatory Peritoneal Dialysis: A Propensity Score Matching Analysis
INTRODUCTION The impact of peritoneal dialysis modality on patient survival and peritonitis rates is not fully understood, and no large-scale randomized clinical trial (RCT) is available. In the absence of a RCT, the use of an advanced matching procedure to reduce selection bias in large cohort studies may be the best approach. The aim of this study is to compare automated peritoneal dialysis (...
متن کاملThe outcomes of continuous ambulatory and automated peritoneal dialysis are similar.
Recent reports indicate a decreased mortality risk for patients on chronic peritoneal dialysis in the United States. We sought to determine whether a higher use of automated versus continuous ambulatory peritoneal dialysis was associated with this improvement. Analyses were carried out using data from the United States Renal Data System on 66,381 incident patients on chronic peritoneal dialysis...