An assessment of eddy current sensitivity and correction in single-shot diffusion-weighted imaging.
نویسندگان
چکیده
Artefacts caused by eddy currents are a major problem in diffusion weighted imaging. This is particularly acute in experiments in which a number of images with differing degrees of diffusion weighting and/or differently oriented diffusion-weighting gradients need to be combined. The echo-planar imaging sequence is particularly sensitive to the effects of residual eddy currents, especially due to the low bandwidth in the phase-encoding direction. Two published schemes are investigated regarding the effectiveness of eddy current correction. That of Jezzard et al (1998 Magn. Reson. Med. 39 801-12) requires the acquisition of additional experimental data in order to perform a post-acquisition correction, whereas that of Wider et al (1994 J. Magn. Reson. A 108 255-8) attempts to reduce the eddy currents directly. It is found that the latter experiment gives a somewhat superior performance and a combination of the two approaches results in an almost complete elimination of artefact. An alternative single-shot imaging experiment to echo-planar imaging is given by sequences based on fast spin-echo methods, which should be insensitive to the effects of constant eddy currents. It is shown that the intrinsic eddy-current-related artefact level in such experiments is indeed low, residual artefacts being attributed to eddy current decay during the echo train. In situations of poor main magnetic field homogeneity or large eddy currents such sequences may be gainfully used instead of echo-planar imaging.
منابع مشابه
Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...
متن کاملSingle-Shot Diffusion-Weighted Spiral Imaging
Introduction: Spiral trajectories offer a range of desirable properties: short echo times, high SNR efficiency, a uniform point-spread function and a well-conditioned reconstruction problem for high reduction factors in parallel imaging, such as with circular coil-arrays as employed for head MRI. In diffusion weighted MRI (DWI), single-shot spiral imaging could increase the achievable SNR while...
متن کاملGradient preemphasis calibration in diffusion-weighted echo-planar imaging.
This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions....
متن کاملFieldmap-Free Retrospective Registration and Distortion Correction for EPI-based Diffusion-Weighted Imaging
Introduction Acquisition of a set Diffusion Weighted Images (DWIs) allows Diffusion Tensors and Tensor-derived quantities such as Fractional Anisotropy (FA) and Trace (TR) to be computed and used to infer the underlying white matter structure in the brain. DWIs are usually acquired with an echo-planar imaging (EPI) pulse sequence that produces images degraded by B0 field inhomogeneity, eddy cur...
متن کاملEcho Planar Diffusion-weighted Mri of the Abdomen and Pelvis: Comparison of Free- Breathing Monopolar and Bipolar Spin-echo Sequences in Image Quality and Geometric Distortions
Introduction: Diffusion-weighted magnetic resonance imaging (DWI) exploits the random, thermally induced displacement of water molecules in biological tissue. Most DWI applications in the abdomen and pelvis employ single-shot spin-echo echo-planar imaging (ssEPI) due to its fast acquisition times and resultant robust performance against motion artifacts. Nevertheless EPI-based DWI suffers from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 45 12 شماره
صفحات -
تاریخ انتشار 2000