Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS).
نویسندگان
چکیده
The anodic stripping voltammetry at a carbon paste electrode modified with thiol terminated self-assembled monolayer on mesoporous silica (SH-SAMMS) provides a new sensor for simultaneous detection of lead (Pb2+) and mercury (Hg2+) in aqueous solutions. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the stripping analysis. Factors affecting the performance of the SH-SAMMS modified electrodes were investigated, including electrode activation and regeneration, electrode composition, preconcentration time, electrolysis time, and composition of electrolysis and stripping media. The most sensitive and reliable electrode contained 20% SH-SAMMS and 80% carbon paste. The optimal operating conditions were a sequence with a 2 min preconcentration period, then a 60 s electrolysis period of the preconcentrated species in 0.2 M nitric acid, followed by square wave anodic stripping voltammetry from -1.0 V to 0.6 V in 0.2 M nitric acid. The areas of the peak responses were linear with respect to metal ion concentrations in the ranges of 10-1500 ppb Pb2+ and 20-1600 ppb Hg2+. The detection limits for Pb2+ and Hg2+ were 0.5 ppb Pb2+ and 3 ppb Hg2+ after a 20 min preconcentration period.
منابع مشابه
Simultaneous detection of cadmium, copper, and lead using a carbon paste electrode modified with carbamoylphosphonic acid self-assembled monolayer on mesoporous silica (SAMMS)
A new sensor was developed for simultaneous detection of cadmium (Cd2+), copper (Cu2+), and lead (Pb2+), based on the voltammetric response at a carbon paste electrode modified with carbamoylphosphonic acid (acetamide phosphonic acid) self-assembled monolayer (SAM) on mesoporous silica (Ac-Phos SAMMS). The adsorptive stripping voltammetry (AdSV) technique involves preconcentration of the metal ...
متن کاملAutomated portable analyzer for lead(II) based on sequential flow injection and nanostructured electrochemical sensors.
A fully automated portable analyzer for toxic metal ion detection based on a combination of a nanostructured electrochemical sensor and a sequential flow injection system has been developed in this work. The sensor was fabricated from a carbon paste electrode modified with acetamide phosphonic acid self-assembled monolayer on mesoporous silica (Ac-Phos SAMMS) which was embedded in a very small ...
متن کاملVoltammetric analysis of europium at screen-printed electrodes modified with salicylamide self-assembled on mesoporous silica.
Mercury-free sensors for europium (Eu(3+)) assay based on the chemical modification of screen-printed carbon electrodes (SPCEs) with self-assembled salicylamide on mesoporous silica (Sal-SAMMS) have been developed. The preconcentration of Eu(3+) at SAMMS-based sensors utilizes the binding affinity of the salicylamide and Eu(3+), accomplished at open circuit potential without electrolyte and sol...
متن کاملAn Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions
In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...
متن کاملVoltammetric determination of cysteine at a carbon paste electrode modified with Cu(II)-salen complex
The electrochemical behavior of a modified carbon paste electrode (MCPE) with N,N′ethylenbis(salicylideneiminato)copper(II) complex ([Cu(II)-Salen]) was investigated as a newsensor for cystein. The Britton-Robinson buffer with pH 5, 10% modifier in electrode, potentialscanning rate of 20 mVs-1 and puls height of 50 mV were used as the optimum condition for thedetermination of cysteine using car...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 128 5 شماره
صفحات -
تاریخ انتشار 2003